Validation of a Markerless Non-Contact Gait Analysis System for Three-Dimensional Gait Kinematics in Patients with Ankle Injuries: A Concurrent Comparison Study with the Vicon Three-Dimensional Motion Capture System
Sensors · 19.07.2026 · 26 (14) · 4579
DOI: 10.3390/s26144579 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Sensors, online erschienen am 19.07.2026. Verfasst von Xuhan Cao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing 100191, China. Hauptthemen laut MEDLINE: Ankle Injuries, Gait Analysis, Gait, Imaging, Three-Dimensional. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing Natural Science Foundation, Beijing Natural Science Foundation-Haidian Original Innovation Joint Fund.
Abstract (Originalsprache)
(1)
Background
This study validated the accuracy of a markerless gait analysis system, Foot4D, against the Vicon 3D motion capture system in 60 patients with ankle injuries. (2)
Methods
Synchronized gait data were collected using both systems while participants walked on a treadmill at self-selected speeds. The Foot4D system employs a Vision Transformer (ViT-H/16) encoder and the SKEL parametric model for markerless 3D pose reconstruction from multi-view depth cameras. Spatiotemporal gait parameters and lower limb 3D kinematics (hip, knee, and ankle) were compared using ICC, Bland–Altman analysis, and MAE. (3)
Results
All 12 spatiotemporal parameters showed good-to-excellent agreement (ICC = 0.738–0.999, MAE = 0.009–0.108 m/s). Agreement for joint kinematics decreased from proximal to distal: hip (mean ICC ≈ 0.947, MAE 1.16–1.52°), knee (mean ICC ≈ 0.921, MAE 1.17–1.75°), and ankle (mean ICC ≈ 0.839). Ankle sagittal plane ROM demonstrated good agreement (ICC = 0.857–0.911), while the frontal (ICC ≈ 0.807) and transverse (ICC ≈ 0.816–0.835) planes were at the lower bound of good agreement, with a −3.19° systematic bias in the injured ankle sagittal plane. (4)
Conclusions
Foot4D is clinically reliable for spatiotemporal and proximal joint kinematic assessment, though ankle multiplanar motion measurement warrants further algorithmic optimization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing 100191, China.
- Beijing Key Laboratory of Research and Translation for Drugs and Medical Devices in Precision Diagnosis and Treatment of Sports Injuries, Beijing 100191, China.
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing 100191, China.
- Department of Engineering Physics, Key Laboratory of Particle and Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China.
- College of Mechanical & Energy Engineering, Beijing University of Technology, Beijing 100124, China.
ORCID-Profile: Xuhan Cao, Mingjie Dong, Shuang Ren, Qinwei Guo
Förderung
- Beijing Natural Science Foundation
- Beijing Natural Science Foundation-Haidian Original Innovation Joint Fund
Zitieren
APA
Cao, X., Zhou, Q., Wang, S., Dong, M., Ren, S., & Guo, Q. (2026). Validation of a Markerless Non-Contact Gait Analysis System for Three-Dimensional Gait Kinematics in Patients with Ankle Injuries: A Concurrent Comparison Study with the Vicon Three-Dimensional Motion Capture System. Sensors, 26(14), 4579. https://doi.org/10.3390/s26144579
Vancouver
Cao X, Zhou Q, Wang S, Dong M, Ren S, Guo Q. Validation of a Markerless Non-Contact Gait Analysis System for Three-Dimensional Gait Kinematics in Patients with Ankle Injuries: A Concurrent Comparison Study with the Vicon Three-Dimensional Motion Capture System. Sensors. 2026;26(14):4579. doi:10.3390/s26144579
BibTeX
@article{Cao2026,
author = {Cao, Xuhan and Zhou, Qing and Wang, Shuo and Dong, Mingjie and Ren, Shuang and Guo, Qinwei},
title = {Validation of a Markerless Non-Contact Gait Analysis System for Three-Dimensional Gait Kinematics in Patients with Ankle Injuries: A Concurrent Comparison Study with the Vicon Three-Dimensional Motion Capture System},
journal = {Sensors},
year = {2026},
volume = {26},
number = {14},
pages = {4579},
doi = {10.3390/s26144579}
}
EUVIMED