Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds
Sensors · 16.07.2026 · 26 (14) · 4520
DOI: 10.3390/s26144520 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 16.07.2026. Verfasst von Trung T Le und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, School of Engineering, Mercer University, Macon, GA 31207, USA. Hauptthemen laut MEDLINE: Lower Extremity, Gait, Walking Speed, Walking. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Mercer On Mission-Prosthetic Program.
Abstract (Originalsprache)
Background
Wearable inertial measurement units (IMoCAPs) are increasingly used in clinical gait analysis due to their portability and ability to capture data outside laboratory settings; however, validation across operating conditions is essential.
Objective
To evaluate the concurrent validity and reliability of the Noraxon Ultium™ IMU system against a Vicon optical motion capture (OMC) system for lower-limb kinematics during walking across different speeds and time intervals.
Methods
Ten healthy adults performed overground walking at slow, normal, and fast self-selected speeds. Kinematics were recorded simultaneously using both systems. Discrete variables (Max, Min, ROM) were analyzed using three-factor repeated-measures ANOVA (Device × Speed × Time, p < 0.05). Agreement was assessed using Bland–Altman analysis, RMSE, and ICC (3,1), and waveform differences were evaluated using Statistical Parametric Mapping (SPM).
Results
Time effects were minimal across all planes. Sagittal-plane kinematics showed strong agreement, with small biases (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, School of Engineering, Mercer University, Macon, GA 31207, USA.
- Department of Interdisciplinary Engineering, College of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.
- Department of Orthopedic Surgery, School of Medicine, Mercer University, Macon, GA 31207, USA.
ORCID-Profile: Trung T Le, Scott C E Brandon
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Mercer On Mission-Prosthetic Program
Zitieren
APA
Le, T. T., Vo, H. V., & Brandon, S. C. E. (2026). Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds. Sensors, 26(14), 4520. https://doi.org/10.3390/s26144520
Vancouver
Le TT, Vo HV, Brandon SCE. Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds. Sensors. 2026;26(14):4520. doi:10.3390/s26144520
BibTeX
@article{Le2026,
author = {Le, Trung T and Vo, Ha V and Brandon, Scott C E},
title = {Concurrent Validity and Reliability Between Noraxon Ultium™ IMU and Vicon OMC for Lower Limb Gait Assessment Across Variable Walking Speeds},
journal = {Sensors},
year = {2026},
volume = {26},
number = {14},
pages = {4520},
doi = {10.3390/s26144520}
}
EUVIMED