Inter‐Session Repeatability of a Smartphone‐Based Markerless System to Measure Segment Length and Lower‐Limb Kinematics in Patients With End‐Stage Knee Osteoarthritis
Orthopaedic Surgery · 2026-11 · 18 (11) · 2452-2462
DOI: 10.1111/os.70431 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Surgery, online erschienen am 17.09.2026. Verfasst von Chunping Ye und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China. Hauptthemen laut MEDLINE: Osteoarthritis, Knee, Smartphone, Lower Extremity. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Key Research and Development Program of China, West China Hospital, Sichuan University, Sichuan Provincial International Science and Technology Innovation Cooperation.
Abstract (Originalsprache)
Background
While kinematic analysis is crucial to characterize multi‐planar functional deficits in end‐stage knee osteoarthritis (OA), traditional laboratories impose severe physical burdens on patients. In‐field markerless systems like OpenCap offer an accessible alternative, yet their repeatability in this population remains underexplored. The objective of this study was to assess the inter‐session repeatability of OpenCap for quantifying segment lengths and lower‐limb kinematics during gait and sit‐to‐stand tasks in end‐stage knee osteoarthritis (OA) patients.
Methods
Twenty‐three patients with end‐stage knee OA scheduled for total knee arthroplasty performed gait and sit‐to‐stand tasks while wearing street clothes across two visits. Segment lengths obtained from static calibration were compared between sessions, while waveform repeatability of lower‐limb joint angles was assessed using root mean square deviation (RMSD) and intraclass correlation coefficient (ICC). Additionally, the standard error of measurement (SEM) and minimal detectable change (MDC) were calculated for discrete kinematic parameters.
Results
The segment lengths exhibited moderate to excellent repeatability between sessions (mean ICC : 0.79). Measurement bias was generally minimal (< 0.5 cm, except for the upper arm), with the overall 95% limits of agreement ranging from −4.51 to 3.98 cm. For gait, the average RMSD and ICC values were 4.0° ( SD : 0.9) and 0.82 ( SD : 0.07), respectively, whereas for the sit‐to‐stand task, these values were 5.2° ( SD : 1.1) and 0.69 ( SD : 0.08), respectively. The average SEM and MDC values for gait were 2.9° and 8.0°, and for sit‐to‐stand, 3.0° and 8.4°, respectively.
Conclusions
OpenCap demonstrates moderate to good inter‐session repeatability for static anatomical measurements and gait kinematics in patients with end‐stage knee OA, showing promise as a low‐burden clinical assessment tool. However, the higher variability observed during the sit‐to‐stand task necessitates cautious, task‐specific interpretation, underscoring the need for further improvements before expanding its use across broader functional assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.
- School of Physical Education, Tianfu College of Southwestern University of Finance and Economics, Mianyang, Sichuan Province, China.
- Information Technology Center, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.
- Department of Orthopedic Surgery and West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.
ORCID-Profile: Renxin Ding, Yong Nie, Kang Li
Förderung
- National Key Research and Development Program of China
- West China Hospital, Sichuan University
- Sichuan Provincial International Science and Technology Innovation Cooperation
- Advanced Materials - National Science and Technology Major Project
Zitieren
APA
Ye, C., Ding, R., Wang, J., Nie, Y., & Li, K. (2026). Inter‐Session Repeatability of a Smartphone‐Based Markerless System to Measure Segment Length and Lower‐Limb Kinematics in Patients With End‐Stage Knee Osteoarthritis. Orthopaedic Surgery, 18(11), 2452-2462. https://doi.org/10.1111/os.70431
Vancouver
Ye C, Ding R, Wang J, Nie Y, Li K. Inter‐Session Repeatability of a Smartphone‐Based Markerless System to Measure Segment Length and Lower‐Limb Kinematics in Patients With End‐Stage Knee Osteoarthritis. Orthopaedic Surgery. 2026;18(11):2452-2462. doi:10.1111/os.70431
BibTeX
@article{Ye2026,
author = {Ye, Chunping and Ding, Renxin and Wang, Junqing and Nie, Yong and Li, Kang},
title = {Inter‐Session Repeatability of a Smartphone‐Based Markerless System to Measure Segment Length and Lower‐Limb Kinematics in Patients With End‐Stage Knee Osteoarthritis},
journal = {Orthopaedic Surgery},
year = {2026},
volume = {18},
number = {11},
pages = {2452--2462},
doi = {10.1111/os.70431}
}
EUVIMED