EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In Situ Cold-Junction Compensation Strategy for Semiconductor Thin-Film Thermocouples Based on a Pt Thin-Film Resistance Temperature Detector

Yuelong Li, Lantian Tang, Zhixuan Su, Yi Xu, Xianwei Qian, Yifan Wang, Qinnan Chen, Chao Wu

Sensors · 08.07.2026 · 26 (14) · 4337

DOI: 10.3390/s26144337 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 08.07.2026. Verfasst von Yuelong Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Electrical Engineering, Pen-Tung Sah Institute of Micro-Nano Science & Technology, Xiamen University, Xiamen 361005, Chi…. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, the 2024 externally commissioned project of Sichuan Gas Turbine Research Institute of AECC, Sichuan Gas Turbine Research Institute of AECC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Semiconductor thin-film thermocouples offer significant advantages for in situ temperature monitoring in advanced engineering equipment. However, the absence of a reliable cold-junction temperature compensation methodology has constrained their practical deployment. This study proposes an in situ cold-junction compensation strategy based on a Pt thin-film resistance temperature detector (RTD), wherein the Pt thin-film RTD is conformally integrated with an ITO–In2O3 thin-film thermocouple via sputtering and printing processes, enabling precise acquisition of cold-junction temperature without external temperature control apparatus. The fabricated Pt thin-film RTD exhibits a coefficient of determination of 0.99995 over the temperature range from ambient to 300 °C, with a temperature coefficient of resistance of 3810.09 ppm/°C, a maximum fitting error of merely 1.02 °C, repeatability precision superior to 1.46 °C, temperature resolution better than 0.2 °C, and a long-term drift rate as low as 0.006%/h. Under simulated practical operating scenarios, the RTD demonstrates superior thermal tracking performance relative to surface-mounted thermocouples. Conformal device fabrication is further realized on the curved surface of a turbine blade, where the RTD maintains characteristics consistent with those on planar substrates, and effective compensation up to 124 °C is achieved in butane flame thermal shock experiments. This strategy overcomes the limitation of conventional compensation methods to planar substrates, furnishing a reliable solution for high-precision in situ temperature monitoring on curved structures of hot-section components via semiconductor thin-film thermocouples.

Schlagwörter

Stichwörter der Autor:innen

ITO–In2O3Pt thin-film temperature detectorcold-junction compensationin situ temperature monitoringsemiconductor thin-film thermocouple

Autor:innen und Institutionen

  • Department of Mechanical and Electrical Engineering, Pen-Tung Sah Institute of Micro-Nano Science & Technology, Xiamen University, Xiamen 361005, China.
  • Research Institute Aero-Engine, Beihang University, Beijing 100191, China.
  • AECC Sichuan Gas Turbine Research Establishment, Chengdu 610500, China.
  • Department of Mechanical Engineering, University of California at Berkeley, Berkeley, CA 94720, USA.

Förderung

  • National Natural Science Foundation of China
  • the 2024 externally commissioned project of Sichuan Gas Turbine Research Institute of AECC
  • Sichuan Gas Turbine Research Institute of AECC

Zitieren

APA

Li, Y., Tang, L., Su, Z., Xu, Y., Qian, X., Wang, Y., Chen, Q., & Wu, C. (2026). In Situ Cold-Junction Compensation Strategy for Semiconductor Thin-Film Thermocouples Based on a Pt Thin-Film Resistance Temperature Detector. Sensors, 26(14), 4337. https://doi.org/10.3390/s26144337

Vancouver

Li Y, Tang L, Su Z, Xu Y, Qian X, Wang Y, et al. In Situ Cold-Junction Compensation Strategy for Semiconductor Thin-Film Thermocouples Based on a Pt Thin-Film Resistance Temperature Detector. Sensors. 2026;26(14):4337. doi:10.3390/s26144337

BibTeX
@article{Li2026,
  author = {Li, Yuelong and Tang, Lantian and Su, Zhixuan and Xu, Yi and Qian, Xianwei and Wang, Yifan and Chen, Qinnan and Wu, Chao},
  title = {In Situ Cold-Junction Compensation Strategy for Semiconductor Thin-Film Thermocouples Based on a Pt Thin-Film Resistance Temperature Detector},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4337},
  doi = {10.3390/s26144337}
}
Kostenlos starten →