Static Calibration and Wiring-Configuration-Dependent Performance of NiCr-Based Thin-Film Thermocouples

Wenqian Yuan, Zhongfeng Kang iD

Micromachines · 20.06.2026 · 17 (6) · 746

DOI: 10.3390/mi17060746 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 20.06.2026. Verfasst von Wenqian Yuan und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Science and Engineering, Lanzhou University, Lanzhou 730000, China. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Gansu Province, China, Talent Scientific Fund of Lanzhou University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thin-film thermocouples (TFTCs) offer conformal sensing junctions with minimal thermal mass, enabling rapid transient response and direct deposition on curved or moving components, which are difficult to achieve using conventional wire thermocouples in applications such as high-speed machining, electric powertrain thermal management, and fuel-cell monitoring. In practical deployment, the effective accuracy of a TFTC can also be affected by the measurement setup used for calibration and testing, particularly lead-wire material transitions, cold-junction compensation, and wiring-related thermoelectric offsets. This study presents a systematic static calibration and performance evaluation of NiCr-based TFTCs under standardised laboratory conditions, with repeated measurements across the 20–260 °C range using both copper leads and matched compensation wires. The thermoelectric output exhibits excellent linearity; temperature reconstruction against a traceable standard reference yields a maximum deviation of approximately 0.27 °C, with root-mean-square and relative errors within tight bounds. Short-term extended-range verification up to 1000 °C confirms detectable thermoelectric signal generation under the present test conditions. A calibration data packet framework containing the calibrated TFTC sample, wiring configuration, calibration coefficients, validity range, and a GUM-compliant uncertainty budget is proposed to support consistent interpretation of calibration results in future digital integration. The study therefore provides a structured calibration workflow and uncertainty-reporting basis for the tested flexible NiCr-based TFTC configurations, supporting further reliability assessment, material-level characterisation, and digital integration.

Schlagwörter

Stichwörter der Autor:innen

NiCr/NiSiSeebeck coefficientstatic calibrationtemperature measurementthin-film thermocoupleuncertainty analysis

Autor:innen und Institutionen

  • School of Information Science and Engineering, Lanzhou University, Lanzhou 730000, China.

ORCID-Profile: Zhongfeng Kang

Förderung

  • Natural Science Foundation of Gansu Province, China
  • Talent Scientific Fund of Lanzhou University

Zitieren

APA

Yuan, W., & Kang, Z. (2026). Static Calibration and Wiring-Configuration-Dependent Performance of NiCr-Based Thin-Film Thermocouples. Micromachines, 17(6), 746. https://doi.org/10.3390/mi17060746

Vancouver

Yuan W, Kang Z. Static Calibration and Wiring-Configuration-Dependent Performance of NiCr-Based Thin-Film Thermocouples. Micromachines. 2026;17(6):746. doi:10.3390/mi17060746

BibTeX
@article{Yuan2026,
  author = {Yuan, Wenqian and Kang, Zhongfeng},
  title = {Static Calibration and Wiring-Configuration-Dependent Performance of NiCr-Based Thin-Film Thermocouples},
  journal = {Micromachines},
  year = {2026},
  volume = {17},
  number = {6},
  pages = {746},
  doi = {10.3390/mi17060746}
}
Kostenlos starten →