Design and Field Validation of an Offline Synchronized Multi-Sensor DAQ System for Bridge Structural Health Monitoring
Sensors · 05.07.2026 · 26 (13) · 4274
DOI: 10.3390/s26134274 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 05.07.2026. Verfasst von Guillermo Alandí und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Multidisciplinary Mathematics, Polytechnic University of Valencia, Camino de Vera, s/n, 46022 Valencia, Spain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Structural Health Monitoring (SHM) of large-span bridges requires dense sensor networks to accurately capture dynamic and kinematic behaviors. Traditional commercial systems rely on complex wiring or wireless protocols that frequently suffer from data loss, high power consumption, and synchronization phase errors, which are detrimental to Operational Modal Analysis (OMA). To address these limitations, this study presents the design, development, and field validation of a custom, offline-synchronized multi-sensor Data Acquisition (DAQ) system. Two specialized sensor nodes were developed: (i) an inertial node integrating a low-noise triaxial MEMS accelerometer (ADXL355); and (ii) a displacement node featuring a 24-bit Analog-to-Digital Converter (ADS1220) for displacement sensors. Both nodes share an ultra-low-power microcontroller (STM32L431) and utilize a local microSD storage strategy with an intermediate pseudo-SRAM buffer. To ensure precise temporal alignment without wireless communication overhead, each node incorporates a temperature-compensated Real-Time Clock (DS3231) for offline timestamp synchronization. The system was validated during a field campaign on the Spyckstraße bridge (Germany), deploying a hardware pool of 53 physical DAQ nodes to monitor 118 distinct geometric measurement points (106 inertial, 12 displacement) through a hybrid strategy of fixed and roving setups. The proposed system achieved reliable, low-noise measurements and enabled accurate extraction of operational mode shapes, demonstrating its viability as a robust, cost-effective solution for large-scale infrastructure monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Multidisciplinary Mathematics, Polytechnic University of Valencia, Camino de Vera, s/n, 46022 Valencia, Spain.
- Idvia 2020 Horizonte 2020 SL, Plaza Bandas de Música 5, Local 11, 46013 Valencia, Spain.
ORCID-Profile: Guillermo Alandí
Zitieren
APA
Alandí, G., Real, J. I., Mateo, S., & Cabezas, R. A. (2026). Design and Field Validation of an Offline Synchronized Multi-Sensor DAQ System for Bridge Structural Health Monitoring. Sensors, 26(13), 4274. https://doi.org/10.3390/s26134274
Vancouver
Alandí G, Real JI, Mateo S, Cabezas RA. Design and Field Validation of an Offline Synchronized Multi-Sensor DAQ System for Bridge Structural Health Monitoring. Sensors. 2026;26(13):4274. doi:10.3390/s26134274
BibTeX
@article{Aland2026,
author = {Alandí, Guillermo and Real, Julia Irene and Mateo, Salvador and Cabezas, Reynaldo Antonio},
title = {Design and Field Validation of an Offline Synchronized Multi-Sensor DAQ System for Bridge Structural Health Monitoring},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4274},
doi = {10.3390/s26134274}
}