A Gated Multi-Objective Learning-to-Optimize Framework for Fault-Tolerant Sensor Placement in Bridge Structural Health Monitoring
Sensors · 31.10.2026 · 26 (21) · 6915
DOI: 10.3390/s26216915 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 31.10.2026. Verfasst von Oumayma Najem und 3 weiteren Autor:innen. Beteiligte Einrichtung: Systems Engineering, Modeling and Analysis Laboratory, Faculty of Sciences, Sidi Mohamed Ben Abdellah University, Fez 30500, Morocco. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Center for Scientific and Technical Research (CNRST).
Abstract (Originalsprache)
Structural Health Monitoring (SHM) relies on sensor placement to collect structurally relevant data, which are then interpreted according to the monitoring objective. Optimal Sensor Placement is therefore an essential step for collecting useful information for the monitoring task. However, conventional SHM design often separates the OSP and interpretation steps. Additionally, OSP approaches generally require a separate optimization process for each structural case. This study proposes L2O-OSP, a learning-to-optimize framework that learns sensor placement decisions across a population of bridge configurations. The architecture contains three components: a gating network that determines the sensor budget and the relative weights of the placement objectives; a selector network that ranks candidate response locations and retains the top-k candidates; and a prediction network that estimates severity from the selected structural responses. The placement objective combines prediction error, spatial coverage, sensor count, and a robustness-related term. The framework is evaluated using 2000 parametrically generated bridge configurations and three numerical loading cases per configuration. The model trained without sensor failures selected an average of 74.40 sensors from 180 candidate locations, a reduction of 58.67%, and achieved a severity MAE of 0.02389 with all selected sensors available. At 50% test sensor failure, its MAE increased to 0.03557 without retraining. We compare global severity-oriented ranking with L2O-OSP at matched sensor count; both methods achieved similar prediction errors, but L2O-OSP reduced the mean largest uncovered interval from 9.56% to 3.09% of the bridge span. Additional evaluations examined Gaussian measurement noise, candidate-count sensitivity, and generalization to bridge lengths outside the training range. These findings support the proposed multi-objective approach within the evaluated numerical setting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Systems Engineering, Modeling and Analysis Laboratory, Faculty of Sciences, Sidi Mohamed Ben Abdellah University, Fez 30500, Morocco.
- L3IA Laboratory, Faculty of Sciences, Sidi Mohamed Ben Abdellah University, Fez 30500, Morocco.
ORCID-Profile: Mohammed Benbrahim, Mohammed Nabil Kabbaj
Förderung
- National Center for Scientific and Technical Research (CNRST)
Zitieren
APA
Najem, O., Benbrahim, M., Kabbaj, M. N., & Boumhidi, J. (2026). A Gated Multi-Objective Learning-to-Optimize Framework for Fault-Tolerant Sensor Placement in Bridge Structural Health Monitoring. Sensors, 26(21), 6915. https://doi.org/10.3390/s26216915
Vancouver
Najem O, Benbrahim M, Kabbaj MN, Boumhidi J. A Gated Multi-Objective Learning-to-Optimize Framework for Fault-Tolerant Sensor Placement in Bridge Structural Health Monitoring. Sensors. 2026;26(21):6915. doi:10.3390/s26216915
BibTeX
@article{Najem2026,
author = {Najem, Oumayma and Benbrahim, Mohammed and Kabbaj, Mohammed Nabil and Boumhidi, Jaouad},
title = {A Gated Multi-Objective Learning-to-Optimize Framework for Fault-Tolerant Sensor Placement in Bridge Structural Health Monitoring},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6915},
doi = {10.3390/s26216915}
}
EUVIMED