Fachartikel in der Zeitschrift Sensors, online erschienen am 03.07.2026. Verfasst von Xiao Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Zhejiang Province Key Laboratory of Optoelectronic Metrology and Precision Instruments, College of Optical and Electronic Technology, China Jiliang U…. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Metal Nanoparticles, Urine, Urinalysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Suqian Sci&Tech Program.
Abstract (Originalsprache)
Urine pH is an important biomarker related to metabolic status and urinary system health, but reliable SERS quantification in real urine remains limited by matrix interference, heterogeneous hotspot distribution, and the narrow response range of single pH-responsive molecules. Here, we report a core–gap–shell Au@1,4-BDT@Au@4-MBA/MPY nanoprobe for ratiometric SERS detection of urine pH. 1,4-BDT was confined within the gap between the gold core and shell as an internal standard, while 4-MBA and 4-MPY were co-assembled on the outer gold shell to provide complementary protonation/deprotonation responses. The internal standard-corrected ratio I1004/I1400/I731 reduced signal fluctuation and enabled segmented linear fitting over pH = 1.0–7.0 and pH = 7.0–10.0, with coefficients of determination of 0.98806 and 0.99989, respectively. The sensing platform also maintained stable ratiometric responses under different interference conditions. In real urine samples from five volunteers, SERS-predicted pH values agreed well with commercial pH meter measurements, with relative accuracies of 98.71–101.9% and RSD values below 2.1%. This confined internal standard and dual-molecule ratiometric strategy provides a feasible approach for urine pH sensing in complex biofluid matrices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Zhejiang Province Key Laboratory of Optoelectronic Metrology and Precision Instruments, College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310018, China.
- Jiangsu Province (Suqian) Hospital, Suqian 223800, China.
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China.
ORCID-Profile: Fan-Li Zhang
Förderung
- Suqian Sci&Tech Program
Zitieren
APA
Wu, X., Wang, A., Cai, X., Zhang, F. L., & Pei, B. (2026). Confined Internal Standard Core–Gap–Shell Nanoprobes for Ratiometric SERS Sensing of Urine pH. Sensors, 26(13), 4205. https://doi.org/10.3390/s26134205
Vancouver
Wu X, Wang A, Cai X, Zhang FL, Pei B. Confined Internal Standard Core–Gap–Shell Nanoprobes for Ratiometric SERS Sensing of Urine pH. Sensors. 2026;26(13):4205. doi:10.3390/s26134205
BibTeX
@article{Wu2026,
author = {Wu, Xiao and Wang, An and Cai, Xiao and Zhang, Fan-Li and Pei, Bing},
title = {Confined Internal Standard Core–Gap–Shell Nanoprobes for Ratiometric SERS Sensing of Urine pH},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4205},
doi = {10.3390/s26134205}
}
EUVIMED