Minimally invasive monitoring of acute liver injury using ROS-responsive gold aggregates for urinary readout
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.119136 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Shaowen Wang und 13 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, South China University of Technology, Guangzhou, Guangdong, 510006, China; National Engineering Research Center for Tissue Restor…. Hauptthemen laut MEDLINE: Gold, Chemical and Drug Induced Liver Injury, Metal Nanoparticles, Biosensing Techniques. Die Arbeit nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Acute liver injury is a life-threatening disorder associated with substantial morbidity and mortality worldwide, underscoring the need for convenient and minimally invasive monitoring. Here, we develop an ALI-responsive nanoprobe that dissociates into renal-clearable gold nanoparticles, facilitating minimally invasive acute liver injury diagnosis through colorimetric urinalysis. This nanoprobe is constructed as a simple nanoaggregate of self-assembled ultrasmall AuNPs linked via a responsive moiety (2,2'-[propane-2,2-diylbis(thio)]diacetic acid). Elevated endogenous reactive oxygen species in the injured liver trigger the dissociation of Au-TKs accumulated in hepatic tissue. The released AuNPs are subsequently excreted into urine and can be quantified by leveraging their peroxidase-like activity and renal-clearable property. This platform outperforms conventional serum-based methods in terms of sensitivity and accuracy for early prediction of acetaminophen-induced liver injury in mice. To enhance practicality, a smartphone application with color capture capability was developed, demonstrating excellent linearity (R2 > 0.95) compared with microplate reader detection. This smartphone-based colorimetric biosensing system, featuring convenient, minimally invasive operation, holds strong potential to transform ALI monitoring through urinary readouts and may provide additional benefits for rapid detection of a broad range of inflammatory diseases by targeting disease-specific pathological signatures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Medicine, South China University of Technology, Guangzhou, Guangdong, 510006, China; National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Guangd…
- National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Guangdong, 510006, China.
- Cancer Centre and Institute of Translational Medicine, Faculty of Health Sciences, University of Macau, Taipa, Macau SAR, 999078, China; State Key Laboratory of Oral Diseases and National Clinical Research Center for Or…
- Cancer Centre and Institute of Translational Medicine, Faculty of Health Sciences, University of Macau, Taipa, Macau SAR, 999078, China.
- Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science (CAS), Suzhou, 215163, China. Electronic address: cl1221@mail.ustc.edu.cn.
- National Engineering Research Center of Immunological Products, Third Military Medical University, Chongqing, 400038, China. Electronic address: guanshan87@163.com.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, S., Fang, H., Xie, X., Wu, Z., Xiao, K., Jiang, Y., Zhao, X., Chen, F., Chen, X., Du, B., Cao, L., Guan, S., Shao, D., & Cui, M. (2026). Minimally invasive monitoring of acute liver injury using ROS-responsive gold aggregates for urinary readout. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119136
Vancouver
Wang S, Fang H, Xie X, Wu Z, Xiao K, Jiang Y, et al. Minimally invasive monitoring of acute liver injury using ROS-responsive gold aggregates for urinary readout. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.119136
BibTeX
@article{Wang2026,
author = {Wang, Shaowen and Fang, Hui and Xie, Xiaochun and Wu, Ziping and Xiao, Kai and Jiang, Yongwei and Zhao, Xin and Chen, Fangman and Chen, Xiaoyu and Du, Bujie and Cao, Lei and Guan, Shan and Shao, Dan and Cui, Miao},
title = {Minimally invasive monitoring of acute liver injury using ROS-responsive gold aggregates for urinary readout},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.119136}
}
EUVIMED