EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Evaluation of the Ergomechanic Markerless Motion Capture System for Lower Body Kinematics During Standing, Squatting, and Walking

Simon M Harrison iD, Raymond C Z Cohen, Scott C Starkey, Jayan Greenwood, Ernest Cheong, Khoi Nguyen, N H Phu Trinh, Tomislav Baček, Denny Oetomo

Journal of Biomechanical Engineering · 2025

DOI: 10.1115/1.4069821 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Simon M Harrison und 8 weiteren Autor:innen. Beteiligte Einrichtung: Data61, CSIRO, Clayton, VIC 3168, Australia. Hauptthemen laut MEDLINE: Walking, Mechanical Phenomena, Standing Position, Lower Extremity. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Markerless motion capture (MMC) shows promise for examining human movement across many domains because of its nonintrusive nature and negligible per-subject setup time. However, published MMC systems typically require specific hardware. This validation study compared lower-body joint kinematics from Ergomechanic, a hardware-agnostic pose model-based MMC system, to an established marker-based motion capture (MBMC) system. Static trial data from eighteen people were used to register MMC keypoints within a widely used musculoskeletal model. The registered model was used to calculate joint kinematics for static pose, squatting, and walking trials. A novel perturbation analysis estimated the contributions to differences in MBMC and MMC approaches to measurement disparities. Very good (0.87–1.0) correlations between the systems were calculated for ankle, knee, and hip flexion–extension angles. Good (0.70-0.86) correlations were found for hip external–internal and abduction–adduction. Pelvis and lumbar spine angles had a wider range of correlation results (-0.06 to 0.95), likely due to the few MMC keypoints in these body regions. Relative contributions from the perturbation analysis were (i) 75% from variations in MMC data relative to MBMC; (ii) 8% because MMC keypoints (26) < MBMC markers (67); and (iii) 3% from differences in musculoskeletal model scaling. These results validate Ergomechanic for leg kinematics during standing, walking, and squatting. Further, they suggest system improvements for pelvis and torso kinematics and provide new insights into the sources of known differences between MMC and MBMC measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WalkingMechanical PhenomenaStanding PositionLower ExtremityPostureHumansBiomechanical PhenomenaMaleFemaleAdultYoung AdultMovementMotion Capture

Autor:innen und Institutionen

  • Data61, CSIRO, Clayton, VIC 3168, Australia.
  • Centre for Health, Exercise and Sports Medicine, Department of Physiotherapy, The University of Melbourne, Parkville, VIC 3010, Australia.
  • The University of Melbourne.
  • Human Robotics Lab, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC 3010, Australia.

ORCID-Profile: Simon M Harrison

Zitieren

APA

Harrison, S. M., Cohen, R. C. Z., Starkey, S. C., Greenwood, J., Cheong, E., Nguyen, K., Trinh, N. H. P., Baček, T., & Oetomo, D. (2025). Evaluation of the Ergomechanic Markerless Motion Capture System for Lower Body Kinematics During Standing, Squatting, and Walking. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4069821

Vancouver

Harrison SM, Cohen RCZ, Starkey SC, Greenwood J, Cheong E, Nguyen K, et al. Evaluation of the Ergomechanic Markerless Motion Capture System for Lower Body Kinematics During Standing, Squatting, and Walking. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4069821

BibTeX
@article{Harrison2025,
  author = {Harrison, Simon M and Cohen, Raymond C Z and Starkey, Scott C and Greenwood, Jayan and Cheong, Ernest and Nguyen, Khoi and Trinh, N H Phu and Baček, Tomislav and Oetomo, Denny},
  title = {Evaluation of the Ergomechanic Markerless Motion Capture System for Lower Body Kinematics During Standing, Squatting, and Walking},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  doi = {10.1115/1.4069821}
}
Kostenlos starten →