Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace
Sensors · 28.05.2026 · 26 (11) · 3421
DOI: 10.3390/s26113421 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 28.05.2026. Verfasst von Seth Donahue und 9 weiteren Autor:innen. Beteiligte Einrichtung: Shriners Children's Lexington, Lexington, KY 40508, USA. Hauptthemen laut MEDLINE: Motion Capture, Upper Extremity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study validates a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using monocular AI-driven Markerless Motion Capture (MMC). Objective validation of such techniques for clinically oriented tasks is essential to support their adoption in clinical motion analysis. Nine adults without impairments performed the standardized UERW task, reaching targets distributed across a virtual sphere centered on the torso and displayed via VR headset. Movements were simultaneously captured with a marker-based system and eight FLIR cameras; monocular analysis was applied to two videos representing frontal and offset camera configurations. Agreement was assessed by comparing the percentage workspacereached across six of eight workspace octants between the systems. The frontal camera demonstrated strong agreement with the marker-based reference (mean bias: 0.61±0.12% reachspace per octant), whereas the offset view underestimated workspace reached −5.66±0.45%. Depth-related errors in the frontal configuration were confined to posterior octants, whereas the offset view introduced inaccuracies in both contralateral and posterior octants. These findings support the feasibility of a frontal monocular camera for UERW assessment, particularly for anterior workspace evaluation. While posterior accuracy remains limited by depth estimation and anatomical occlusion errors, the overall results demonstrate clinical potential for practical, monocular-camera assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shriners Children's Lexington, Lexington, KY 40508, USA.
- Department of Physical Therapy, University of Kentucky, Lexington, KY 40536, USA.
- Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL 60611, USA.
- Department of Physical Medicine and Rehabilitation, Northwestern University, Evanston, IL 60208, USA.
- Department of Kinesiology, School of Behavioral Sciences and Education, Pennsylvania State University at Harrisburg, Middletown, PA 17057, USA.
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
ORCID-Profile: Seth Donahue, J D Peiffer, R Tyler Richardson, May D Wang, R James Cotton
Zitieren
APA
Donahue, S., Peiffer, J. D., Richardson, R. T., Zhong, Y., Tan, S. Q. Y., Marteau, B. L., Russo, S. A., Wang, M. D., Cotton, R. J., & Chafetz, R. (2026). Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace. Sensors, 26(11), 3421. https://doi.org/10.3390/s26113421
Vancouver
Donahue S, Peiffer JD, Richardson RT, Zhong Y, Tan SQY, Marteau BL, et al. Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace. Sensors. 2026;26(11):3421. doi:10.3390/s26113421
BibTeX
@article{Donahue2026,
author = {Donahue, Seth and Peiffer, J D and Richardson, R Tyler and Zhong, Yishan and Tan, Shaun Q Y and Marteau, Benoit L and Russo, Stephanie A and Wang, May D and Cotton, R James and Chafetz, Ross},
title = {Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace},
journal = {Sensors},
year = {2026},
volume = {26},
number = {11},
pages = {3421},
doi = {10.3390/s26113421}
}