EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the Use of a Depth Camera for the Assessment of Upper Extremity Movements in Healthy Individuals

Serkan Çizmecioğulları iD, Şenay Mihçin iD, Aydin Akan iD

Sensors · 11.03.2026 · 26 (6) · 1762

DOI: 10.3390/s26061762 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 11.03.2026. Verfasst von Serkan Çizmecioğulları und 2 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Device Technology Program, Vocational School of Technical Sciences, Kırşehir Ahi Evran University, Kırşehir 40100, Türkiye. Hauptthemen laut MEDLINE: Range of Motion, Articular, Upper Extremity. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Upper extremity impairments often lead to reduced joint range of motion (ROM), making reliable assessment essential for rehabilitation planning. This study investigated the within-day and between-day reliability of the Microsoft Kinect V2 depth camera for active upper extremity ROM assessment in 30 healthy adults. Ten predefined shoulder and elbow movements were recorded, and joint angles were computed using a custom vector-based algorithm. Within-day reliability ranged from moderate to excellent (ICC: 0.754–0.953), while between-day reliability ranged from moderate to good (ICC: 0.654–0.881). Absolute reliability varies substantially across movements. The SEM% values ranged from 2.1% to 17.3% within-day and from 2.8% to 23.6% between-day. The between-day MDC values were particularly high for certain movements (e.g., >20° for shoulder extension and >50° for elbow flexion), indicating limited sensitivity to detect small clinical changes. Additionally, shoulder adduction could not be reliably analyzed in 36.7% of participants due to self-occlusion-related tracking instability, highlighting a practical limitation of the Kinect V2 for certain upper extremity movements. These findings suggest that Kinect V2-based ROM assessment demonstrates acceptable reliability for large-amplitude planar movements under controlled conditions but shows substantial limitations for rotational and occlusion-prone tasks. The device may be suitable for research or screening applications; however, caution is warranted when interpreting small changes in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularUpper ExtremityHumansAdultFemaleMaleMovementMotion CaptureReproducibility of ResultsAlgorithmsElbow JointBiomechanical PhenomenaYoung Adult

Stichwörter der Autor:innen

Kinectrange of motionrehabilitationreliabilitystroke

Autor:innen und Institutionen

  • Biomedical Device Technology Program, Vocational School of Technical Sciences, Kırşehir Ahi Evran University, Kırşehir 40100, Türkiye.
  • Department of Mechanical Engineering, Izmir Institute of Technology, Izmir 35430, Türkiye.
  • Department of Electrical and Electronics Engineering, Izmir University of Economics, Izmir 35330, Türkiye.

ORCID-Profile: Serkan Çizmecioğulları, Şenay Mihçin, Aydin Akan

Zitieren

APA

Çizmecioğulları, S., Mihçin, Ş., & Akan, A. (2026). On the Use of a Depth Camera for the Assessment of Upper Extremity Movements in Healthy Individuals. Sensors, 26(6), 1762. https://doi.org/10.3390/s26061762

Vancouver

Çizmecioğulları S, Mihçin Ş, Akan A. On the Use of a Depth Camera for the Assessment of Upper Extremity Movements in Healthy Individuals. Sensors. 2026;26(6):1762. doi:10.3390/s26061762

BibTeX
@article{izmecioullar2026,
  author = {Çizmecioğulları, Serkan and Mihçin, Şenay and Akan, Aydin},
  title = {On the Use of a Depth Camera for the Assessment of Upper Extremity Movements in Healthy Individuals},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {6},
  pages = {1762},
  doi = {10.3390/s26061762}
}
Kostenlos starten →