EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net

Giulio Montanari iD, Marco Mura iD, Pasquale Di Viesti iD, Elia Vignoli iD, Giorgio Guerzoni iD, Giorgio Matteo Vitetta iD

Sensors · 15.05.2026 · 26 (10) · 3151

DOI: 10.3390/s26103151 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 15.05.2026. Verfasst von Giulio Montanari und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering "Enzo Ferrari", University of Modena and Reggio Emilia, 41125 Modena, Italy. Hauptthemen laut MEDLINE: Radar, Heart. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Contactless vital signs monitoring is becoming increasingly relevant in scenarios where conventional sensors are impractical or not recommended. In this manuscript, a radar-based contactless system for the joint reconstruction of phonocardiogram (PCG) waveforms and cardiac state segmentation is illustrated. The proposed method exploits a self-attention one-dimensional (1D) U-Net fed by a pre-processed radar-derived input to estimate a PCG-like waveform, its envelope, and the four main cardiac phases: S1, systole, S2, and diastole. The accuracy of our method has been assessed on a public synchronized radar–PCG dataset acquired by means of a 24 GHz Doppler radar and a digital stethoscope. On the test subset, the proposed model achieved a 13.4885 dB reduction in log-spectral distance relative to the radar input signal, indicating a marked improvement in waveform fidelity. Segmentation performance also improved, with Micro-F1 increasing from 74.41% to 84.17% and Macro-F1 from 68.40% to 80.43% on average. Experimental results demonstrated the viability of real-time low-power embedded hardware deployment for contactless auscultation and continuous cardiac monitoring applications. The findings confirm that respiratory interference and low-amplitude signals complicate S2 detection, especially when exacerbated by subject motion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadarHeartPhonocardiographySignal Processing, Computer-AssistedHumansAlgorithms

Stichwörter der Autor:innen

1D U-Netbiomedical signal processingcardiac state segmentationcontactless monitoringdeep learningphonocardiogram reconstructionradar sensingself-attention mechanismtime-series analysis

Autor:innen und Institutionen

  • Department of Engineering "Enzo Ferrari", University of Modena and Reggio Emilia, 41125 Modena, Italy.
  • Deep Radars S.r.l., 41125 Modena, Italy.

ORCID-Profile: Giulio Montanari, Marco Mura, Pasquale Di Viesti, Elia Vignoli, Giorgio Guerzoni, Giorgio Matteo Vitetta

Zitieren

APA

Montanari, G., Mura, M., Di Viesti, P., Vignoli, E., Guerzoni, G., & Vitetta, G. M. (2026). A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net. Sensors, 26(10), 3151. https://doi.org/10.3390/s26103151

Vancouver

Montanari G, Mura M, Di Viesti P, Vignoli E, Guerzoni G, Vitetta GM. A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net. Sensors. 2026;26(10):3151. doi:10.3390/s26103151

BibTeX
@article{Montanari2026,
  author = {Montanari, Giulio and Mura, Marco and Di Viesti, Pasquale and Vignoli, Elia and Guerzoni, Giorgio and Vitetta, Giorgio Matteo},
  title = {A Radar-Based Contactless System for Joint Phonocardiogram Reconstruction and Cardiac State Segmentation Using a Self-Attention 1D U-Net},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3151},
  doi = {10.3390/s26103151}
}
Kostenlos starten →