Radar-Based Heart Cardiac Activity Measurements: A Review
Sensors · 29.11.2024 · 24 (23) · 7654
DOI: 10.3390/s24237654 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Sensors, online erschienen am 29.11.2024. Verfasst von Alvaro Frazao und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics Telecommunications and Informatics (DETI), Instituto de Telecomunicações, Universidade de Aveiro, 3810-193 Aveiro, Portugal. Hauptthemen laut MEDLINE: Radar, Heart Rate, Signal Processing, Computer-Assisted, Algorithms. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, FCT/Ministério da Ciência, Tecnologia e Ensino Superior (MCTES), European Union (EU).
Abstract (Originalsprache)
In recent years, with the increased interest in smart home technology and the increased need to remotely monitor patients due to the pandemic, demand for contactless systems for vital sign measurements has also been on the rise. One of these kinds of systems are Doppler radar systems. Their design is composed of several choices that could possibly have a significant impact on their overall performance, more specifically those focused on the measurement of cardiac activity. This review, conducted using works obtained from relevant scientific databases, aims to understand the impact of these design choices on the performance of systems measuring either heart rate (HR) or heart rate variability (HRV). To that end, an analysis of the performance based on hardware architecture, carrier frequency, and measurement distance was conducted for works focusing on both of the aforementioned cardiac parameters, and signal processing trends were discussed. What was found was that the system architecture and signal processing algorithms had the most impact on the performance, with FMCW being the best performing architecture, whereas factors like carrier frequency did not have an impact.This means that newer systems can focus on cheaper, lower-frequency systems without any performance degradation, which will make research easier.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics Telecommunications and Informatics (DETI), Instituto de Telecomunicações, Universidade de Aveiro, 3810-193 Aveiro, Portugal.
- Águeda School of Technology and Management (ESTGA), Instituto de Telecomunicações, Universidade de Aveiro, 3750-127 Águeda, Portugal.
ORCID-Profile: Alvaro Frazao, Pedro Pinho, Daniel Albuquerque
Förderung
- Fundação para a Ciência e Tecnologia
- FCT/Ministério da Ciência, Tecnologia e Ensino Superior (MCTES)
- European Union (EU)
Zitieren
APA
Frazao, A., Pinho, P., & Albuquerque, D. (2024). Radar-Based Heart Cardiac Activity Measurements: A Review. Sensors, 24(23), 7654. https://doi.org/10.3390/s24237654
Vancouver
Frazao A, Pinho P, Albuquerque D. Radar-Based Heart Cardiac Activity Measurements: A Review. Sensors. 2024;24(23):7654. doi:10.3390/s24237654
BibTeX
@article{Frazao2024,
author = {Frazao, Alvaro and Pinho, Pedro and Albuquerque, Daniel},
title = {Radar-Based Heart Cardiac Activity Measurements: A Review},
journal = {Sensors},
year = {2024},
volume = {24},
number = {23},
pages = {7654},
doi = {10.3390/s24237654}
}
EUVIMED