High-Precision and Efficient Calibration of Robot Polishing Systems Using an Adaptive Residual EKF Optimized by MIPO
Sensors · 13.05.2026 · 26 (10) · 3087
DOI: 10.3390/s26103087 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 13.05.2026. Verfasst von Lei Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jilin Province Science and Technology Department, Science and Technology Development Plan Project of Jilin Province, China.
Abstract (Originalsprache)
This paper proposes an adaptive residual extended Kalman filter method optimized by a multi-strategy improved parrot optimization algorithm (MIPO-ARKEKF) to improve the kinematic parameter calibration accuracy and efficiency of robotic polishing systems. To address the limitations of the standard extended Kalman filter (EKF), such as truncation-error accumulation during repeated linearization and sensitivity to manually selected noise parameters, an integrated improvement framework is developed. Specifically, a gradient stabilizer based on state-estimation increments is introduced to alleviate estimation degradation caused by accumulated truncation errors, while the proposed MIPO algorithm is employed to adaptively optimize the process and measurement noise covariance matrices, thereby improving the robustness of parameter identification under practical measurement uncertainty. The calibration process is established on the basis of high-precision external measurement data obtained from the robotic polishing system. In benchmark-function tests, MIPO demonstrates superior convergence performance. In physical experiments based on a KUKA KR210 R2700 robot, the proposed MIPO-ARKEKF method reduces the root mean square positioning error from 0.8927 mm to 0.4858 mm, corresponding to a 45.58% improvement in accuracy. Compared with representative hybrid calibration methods, the proposed method achieves comparable compensation accuracy while reducing computation time by 34.88% to 65.08%. Practical polishing experiments on ultra-low-expansion glass lenses further verify that the proposed method effectively improves end-effector trajectory tracking accuracy and polishing quality, providing an efficient solution for high-precision robotic polishing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130022, China.
- School of Mechatronic Engineering and Automation, Foshan University, Foshan 528225, China.
- China FAW Group Corporation Limited, Changchun 130000, China.
- FAW Tooling Die Manufacturing Co., Ltd., Changchun 130013, China.
- College of Biological and Agricultural Engineering, Jilin University, Changchun 130012, China.
ORCID-Profile: Yuqi Yao, Xinming Zhang, Yiwen Zhang
Förderung
- Jilin Province Science and Technology Department
- Science and Technology Development Plan Project of Jilin Province, China
Zitieren
APA
Wang, L., Yao, Y., Ruan, S., Li, H., Zhang, X., Zhang, Y., Zang, Z., & Yu, Z. (2026). High-Precision and Efficient Calibration of Robot Polishing Systems Using an Adaptive Residual EKF Optimized by MIPO. Sensors, 26(10), 3087. https://doi.org/10.3390/s26103087
Vancouver
Wang L, Yao Y, Ruan S, Li H, Zhang X, Zhang Y, et al. High-Precision and Efficient Calibration of Robot Polishing Systems Using an Adaptive Residual EKF Optimized by MIPO. Sensors. 2026;26(10):3087. doi:10.3390/s26103087
BibTeX
@article{Wang2026,
author = {Wang, Lei and Yao, Yuqi and Ruan, Shouxin and Li, Hainan and Zhang, Xinming and Zhang, Yiwen and Zang, Zihao and Yu, Zhenglei},
title = {High-Precision and Efficient Calibration of Robot Polishing Systems Using an Adaptive Residual EKF Optimized by MIPO},
journal = {Sensors},
year = {2026},
volume = {26},
number = {10},
pages = {3087},
doi = {10.3390/s26103087}
}
EUVIMED