Fachartikel in der Zeitschrift Sensors, online erschienen am 12.05.2026. Verfasst von Kseniya V Serebrennikova und 3 weiteren Autor:innen. Beteiligte Einrichtung: A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, Moscow 119071, Russia. Hauptthemen laut MEDLINE: Indoles, Spectrum Analysis, Raman, Polymers, Metal Nanoparticles. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The fabrication of SERS nanotags with efficient antibody loading and high signal enhancement remains a challenging task for combining surface-enhanced Raman spectroscopy (SERS) and lateral flow immunoassay (LFIA). In this study, bimetallic AuDTNB@PDADTNB@Ag nanoparticles with a polydopamine (PDA)-based internal nanogap were synthesized and functionalized with anti-prolactin monoclonal antibodies to produce SERS nanotags. Here, polydopamine serves both as a spacer providing a nanogap between the core and the shell, and as a reaction layer to capture Raman reporter 5,5′-dithiobis(2-nitrobenzoic acid) (DTNB) within the nanogap. Regimes (conditions, protocols) for conjugating antibodies to AuDTNB@PDADTNB@Ag were selected to preserve both the binding affinity for the target analyte and the Raman activity of the SERS nanotag. The SERS nanotag provides plasmonic absorption for visible colorimetric readout, as well as strong SERS signals for highly sensitive quantitative immunoassay. Measuring the Raman intensities of DTNB in the test zone after performing LFIA made it possible to determine prolactin with a detection limit of 0.2 ng/mL in the working range from 1 to 10 ng/mL. The achieved limit of detection was 10-fold lower than the LFIA coupled with colorimetric readout (4.7 ng/mL). The recoveries of prolactin from spiked serum samples were in the range of 70.2–82.6% with relative standard deviations of 2.3–6.8%. Overall, the AuDTNB@PDADTNB@Ag nanotag demonstrated high stability, Raman activity, and specificity, indicating that the SERS nanotag with PDA-assisted internal nanogap is promising for use in SERS immunoassay of other target analytes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IndolesSpectrum Analysis, RamanPolymersMetal NanoparticlesProlactinImmunoassaySilverHumans

Stichwörter der Autor:innen

SERS nanotagbimetallic AuDTNB@PDADTNB@Ag nanoparticlespolydopamine-mediated internal nanogapprolactinsurface-enhanced Raman scattering (SERS)

Substanzen

polydopamineIndolesPolymersProlactinSilver

Autor:innen und Institutionen

  • A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, Moscow 119071, Russia.

ORCID-Profile: Kseniya V Serebrennikova, Nadezhda S Komova, Anatoly V Zherdev, Boris B Dzantiev

Förderung

  • Russian Science Foundation

Zitieren

APA

Serebrennikova, K. V., Komova, N. S., Zherdev, A. V., & Dzantiev, B. B. (2026). Application of Core–Shell Bimetallic Nanoparticles with Polydopamine-Assisted Nanogap in SERS-Based Lateral Flow Immunoassay of Prolactin. Sensors, 26(10), 3064. https://doi.org/10.3390/s26103064

Vancouver

Serebrennikova KV, Komova NS, Zherdev AV, Dzantiev BB. Application of Core–Shell Bimetallic Nanoparticles with Polydopamine-Assisted Nanogap in SERS-Based Lateral Flow Immunoassay of Prolactin. Sensors. 2026;26(10):3064. doi:10.3390/s26103064

BibTeX
@article{Serebrennikova2026,
  author = {Serebrennikova, Kseniya V and Komova, Nadezhda S and Zherdev, Anatoly V and Dzantiev, Boris B},
  title = {Application of Core–Shell Bimetallic Nanoparticles with Polydopamine-Assisted Nanogap in SERS-Based Lateral Flow Immunoassay of Prolactin},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3064},
  doi = {10.3390/s26103064}
}
Kostenlos starten →