Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 07.09.2026. Verfasst von Xuemin Qin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry a…. Hauptthemen laut MEDLINE: Electrochemical Techniques, Anti-Mullerian Hormone, Metal-Organic Frameworks, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Innovation Project of Guangxi Graduate Education, National Natural Science Foundation of China, Guangxi Science and Technology Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

By exploiting the dual-quenching effect of CuBi2O4@PDA on Sm-MOF@Ag, we developed a signal-on/signal-off electrochemiluminescence (ECL) immunosensor for the sensitive detection of anti-Müllerian hormone (AMH). A novel samarium-based metal-organic framework (Sm-MOF) was employed as the luminophore, with K2S2O8 used as the co-reactant to generate a stable ECL signal. Silver nanoparticles were in situ decorated on the Sm-MOF surface to act as co-reactant accelerators, promoting SO4•- generation and significantly enhancing the ECL intensity. For signal quenching, energy transfer from the Sm-MOF@Ag donor to the CuBi2O4 acceptor was rationally designed based on their matched energy levels, resulting in pronounced attenuation of the ECL emission. Meanwhile, the polydopamine shell further improved the quenching efficiency by scavenging SO4•- radicals. Under optimized conditions, the proposed ECL immunosensor exhibited a wide linear range from 10 fg·mL- 1 to 100 ng·mL- 1 and a detection limit of 2.6 fg·mL- 1. This dual-quenching strategy represents a novel method for the detection of AMH, with substantial potential for implementation in clinical diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesAnti-Mullerian HormoneMetal-Organic FrameworksBiosensing TechniquesLuminescent MeasurementsLimit of DetectionImmunoassaySilverSamariumPolymersHumansIndolesMetal NanoparticlesCopperAnimals

Stichwörter der Autor:innen

Anti-Müllerian hormoneDual-mode quenchingElectrochemiluminescenceImmunosensorMetal-organic framework

Substanzen

Anti-Mullerian HormoneMetal-Organic FrameworksSilverSamariumPolymersIndolespolydopamineCopper

Autor:innen und Institutionen

  • Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Guangxi Key Laboratory of Chemistry and Molecular Engineering of Medicinal Resources, University Engineerin…

Förderung

  • Innovation Project of Guangxi Graduate Education
  • National Natural Science Foundation of China
  • Guangxi Science and Technology Program

Zitieren

APA

Qin, X., Zheng, X., Deng, X., Luo, Z., Hu, S., Li, J., & Deng, B. (2026). A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone. Microchimica Acta, 193(10). https://doi.org/10.1007/s00604-026-08385-w

Vancouver

Qin X, Zheng X, Deng X, Luo Z, Hu S, Li J, et al. A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone. Microchimica Acta. 2026;193(10). doi:10.1007/s00604-026-08385-w

BibTeX
@article{Qin2026,
  author = {Qin, Xuemin and Zheng, Xiangfei and Deng, Xuyang and Luo, Zhi and Hu, Shenglan and Li, Jing and Deng, Biyang},
  title = {A Sm-MOF@Ag electrochemiluminescence immunosensor mediated by CuBi2O4@PDA dual-mode quenching for sensitive detection of anti-Müllerian hormone},
  journal = {Microchimica Acta},
  year = {2026},
  volume = {193},
  number = {10},
  doi = {10.1007/s00604-026-08385-w}
}
Kostenlos starten →