A High-Sensitivity Sweat Glucose Biosensor Enabled by an In Situ Grown NiFe PBA on Porous Pt/Ni/Au-SPE
Sensors · 06.05.2026 · 26 (9) · 2908
DOI: 10.3390/s26092908 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.05.2026. Verfasst von Huajie Shu und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Materials for Intelligent Sensing, GRINM Group Co., Ltd., Beijing 100088, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose, Ferrocyanides, Sweat. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangdong Basic and Applied Basic Research Foundation, Guangdong Provincial Association for Science and Technology, Youth Fund Project of China GRINM.
Abstract (Originalsprache)
As a promising class of catalysts for enzymatic glucose sensors, Prussian blue analogues (PBAs) exhibit exceptional biomimetic activity. However, their performance is often constrained by poor intrinsic conductivity, which typically limits their sensitivity. To address this limitation, this study presents an effective approach using direct in situ growth of PBAs on the electrode substrates, which enables the effective integration of PBA-based electrochemical systems. A porous Ni framework was first electrodeposited onto a screen-printed gold electrode substrate, followed by the reduction of Pt onto the porous Ni. Subsequently, NiFe PBA was synthesized in situ using the porous Pt/Ni structure as a sacrificial template. Functionalized with glucose oxidase (GOx), the PBA/Pt/Ni biosensor exhibited excellent performance for glucose detection in buffer solution, with a high sensitivity of 262.6 μA mM−1·cm−2 and an ultra-low detection limit of 1.45 μM (calculated at a signal-to-noise ratio of 3, S/N = 3). Notably, its sensitivity corresponds to a two-fold enhancement relative to the electrodes modified with commercial Prussian blue using the conventional drop-casting method. Even when tested in human sweat samples, the biosensor achieved a high sensitivity of 236.4 μA mM−1·cm−2 and a linear detection range of 20–1000 μM, with the broad sensing range fully encompassing the typical physiological concentrations of glucose in human sweat. This excellent performance arises from the high specific surface area of the porous Pt/Ni structure and the tight connection between PBA and the sacrificial Ni anode. This research presents a promising design strategy for advanced, wearable, and non-invasive health-monitoring platforms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Advanced Materials for Intelligent Sensing, GRINM Group Co., Ltd., Beijing 100088, China.
- GRINM (Guangdong) Institute for Advanced Materials and Technology, Foshan 528000, China.
- General Research Institute for Nonferrous Metals, Beijing 100088, China.
Förderung
- Guangdong Basic and Applied Basic Research Foundation
- Guangdong Provincial Association for Science and Technology
- Youth Fund Project of China GRINM
Zitieren
APA
Shu, H., Liu, Q., Wei, Q., Mao, C., Wei, F., & Tu, H. (2026). A High-Sensitivity Sweat Glucose Biosensor Enabled by an In Situ Grown NiFe PBA on Porous Pt/Ni/Au-SPE. Sensors, 26(9), 2908. https://doi.org/10.3390/s26092908
Vancouver
Shu H, Liu Q, Wei Q, Mao C, Wei F, Tu H. A High-Sensitivity Sweat Glucose Biosensor Enabled by an In Situ Grown NiFe PBA on Porous Pt/Ni/Au-SPE. Sensors. 2026;26(9):2908. doi:10.3390/s26092908
BibTeX
@article{Shu2026,
author = {Shu, Huajie and Liu, Qinglin and Wei, Qianhui and Mao, Changhui and Wei, Feng and Tu, Hailing},
title = {A High-Sensitivity Sweat Glucose Biosensor Enabled by an In Situ Grown NiFe PBA on Porous Pt/Ni/Au-SPE},
journal = {Sensors},
year = {2026},
volume = {26},
number = {9},
pages = {2908},
doi = {10.3390/s26092908}
}
EUVIMED