EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sequential Injection Analysis of Cholesterol Using an Oxidation–Reduction Electrode Detector

Takato Imanaka, Takashi Masadome iD

Sensors · 2025

DOI: 10.3390/s25185863 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Takato Imanaka und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Chemistry, Shibaura Institute of Technology, Koto-ku, Tokyo 135-8548, Japan. Hauptthemen laut MEDLINE: Cholesterol, Biosensing Techniques, Flow Injection Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A new automated method for the determination of cholesterol in serum was developed by combining sequential injection analysis (SIA) with potentiometric detection using a gold oxidation–reduction potential (ORP) electrode because serum cholesterol is an important indicator of abnormal lipid metabolism, arteriosclerosis, and hypertension in clinical diagnosis. The method is based on enzymatic hydrolysis of cholesterol esters by cholesterol esterase (CE) to yield free cholesterol, followed by oxidation with cholesterol oxidase (COD) to produce hydrogen peroxide. In the presence of horseradish peroxidase (HRP) and potassium ferrocyanide (K4[Fe(CN)6]), hydrogen peroxide oxidizes ferrocyanide to ferricyanide (K3[Fe(CN)6]), and the concentration ratio of ferri-/ferrocyanide is determined potentiometrically. Experimental conditions were optimized as follows: 5.0 mM K4[Fe(CN)6], 2 min reaction time, 0.5 units/mL HRP, 0.75 units/mL COD for free cholesterol, 1.5 units/mL COD and 10.0 units/mL CE for total cholesterol, and 5.0% (w/v) Triton X-100 with 5.0% (v/v) isopropanol as solubilizing agents. Under these conditions, the calibration curve for total cholesterol exhibited a Nernstian slope of 47.6 mV/decade over the range of 1.0 × 10−5–1.0 × 10−3 M, with no significant interference from common serum constituents. This method offers low reagent consumption, high automation, and simple operation, making it promising for clinical cholesterol analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CholesterolBiosensing TechniquesFlow Injection AnalysisOxidation-ReductionElectrodesCholesterol OxidaseFerrocyanidesHumansHydrogen PeroxideHorseradish PeroxidaseFerricyanidesPotentiometrySterol EsteraseGold

Stichwörter der Autor:innen

cholesteroloxidation–reduction electrodepotentiometrysequential injection analysis

Substanzen

CholesterolCholesterol OxidaseFerrocyanidesHydrogen PeroxideHorseradish PeroxidaseFerricyanidesSterol EsteraseGoldpotassium ferrocyanide

Autor:innen und Institutionen

  • Department of Applied Chemistry, Shibaura Institute of Technology, Koto-ku, Tokyo 135-8548, Japan.

ORCID-Profile: Takashi Masadome

Zitieren

APA

Imanaka, T., & Masadome, T. (2025). Sequential Injection Analysis of Cholesterol Using an Oxidation–Reduction Electrode Detector. Sensors. https://doi.org/10.3390/s25185863

Vancouver

Imanaka T, Masadome T. Sequential Injection Analysis of Cholesterol Using an Oxidation–Reduction Electrode Detector. Sensors. 2025. doi:10.3390/s25185863

BibTeX
@article{Imanaka2025,
  author = {Imanaka, Takato and Masadome, Takashi},
  title = {Sequential Injection Analysis of Cholesterol Using an Oxidation–Reduction Electrode Detector},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25185863}
}
Kostenlos starten →