EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Real-Time ECG Artifact Removal for Adaptive Deep Brain Stimulation: A Comparative Study

Lucrezia Silvi, Valentina D'Onofrio iD, Simone Cauzzo, Angelo Antonini iD, Andrea Guerra iD, Camillo Porcaro iD

Sensors · 25.04.2026 · 26 (9) · 2673

DOI: 10.3390/s26092673 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Sensors, online erschienen am 25.04.2026. Verfasst von Lucrezia Silvi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Research to Advance and Innovate Translational Neuroscience (BRAIN Unit), Department of Neuroscience, University of Padova, 35…. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Artifacts, Electrocardiography, Parkinson Disease. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PRIN.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Adaptive deep brain stimulation (aDBS) for Parkinson’s disease (PD) relies on accurate detection of beta oscillatory activity. However, electrocardiographic (ECG) artifacts frequently contaminate local field potentials (LFPs), compromising control algorithms. While offline cleaning methods exist, their feasibility for real-time operation within the strict timing constraints of current sensing-enabled devices remains unknown.

Methods

We evaluated four ECG removal algorithms, template subtraction (TS), singular value decomposition (SVD), extended SVD (eSVD), and the Perceive toolbox (PR), on simulated datasets (contaminated at −30 to +20 dB) and clinical recordings from 20 PD patients. Algorithms were assessed for artifact removal quality (beta power preservation, signal-to-noise ratio) and real-time feasibility (99th percentile processing latency—P99 < 50 ms).

Results

Only TS and standard SVD met the real-time feasibility threshold, with TS achieving superior timing consistency (P99 ≈ 10 ms). eSVD and PR proved incompatible with closed-loop requirements (P99 > 90 ms). While eSVD yielded the highest artifact suppression at extreme contamination, it suffered from poor signal preservation at moderate levels. TS demonstrated the best balance, maintaining beta power accuracy within ±12% across clinically relevant contamination levels.

Conclusions

TS is the recommended method for real-time aDBS applications, offering a safety-critical balance of computational efficiency and biomarker fidelity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationArtifactsElectrocardiographyParkinson DiseaseHumansAlgorithmsSignal Processing, Computer-AssistedSignal-To-Noise RatioLocal Field Potential Measurement

Stichwörter der Autor:innen

ECG artifactParkinson’s diseaseadaptive deep brain stimulationlocal field potentialsreal-time signal processing

Autor:innen und Institutionen

  • Biomedical Engineering Research to Advance and Innovate Translational Neuroscience (BRAIN Unit), Department of Neuroscience, University of Padova, 35122 Padua, Italy.
  • Padova Neuroscience Center (PNC), University of Padova, 35122 Padua, Italy.
  • Department of Neuroscience, University of Padova, 35122 Padua, Italy.
  • Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), San Camillo Hospital, 30126 Venice, Italy.
  • Institute of Cognitive Sciences and Technologies (ISTC), National Research Council (CNR), 00185 Rome, Italy.
  • Center of Human Brain Health, School of Psychology, University of Birmingham, Birmingham B15 2TT, UK.

ORCID-Profile: Valentina D'Onofrio, Angelo Antonini, Andrea Guerra, Camillo Porcaro

Förderung

  • PRIN

Zitieren

APA

Silvi, L., D'Onofrio, V., Cauzzo, S., Antonini, A., Guerra, A., & Porcaro, C. (2026). Real-Time ECG Artifact Removal for Adaptive Deep Brain Stimulation: A Comparative Study. Sensors, 26(9), 2673. https://doi.org/10.3390/s26092673

Vancouver

Silvi L, D'Onofrio V, Cauzzo S, Antonini A, Guerra A, Porcaro C. Real-Time ECG Artifact Removal for Adaptive Deep Brain Stimulation: A Comparative Study. Sensors. 2026;26(9):2673. doi:10.3390/s26092673

BibTeX
@article{Silvi2026,
  author = {Silvi, Lucrezia and D'Onofrio, Valentina and Cauzzo, Simone and Antonini, Angelo and Guerra, Andrea and Porcaro, Camillo},
  title = {Real-Time ECG Artifact Removal for Adaptive Deep Brain Stimulation: A Comparative Study},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {2673},
  doi = {10.3390/s26092673}
}
Kostenlos starten →