EUVIMEDEUVIMED entdecken
Crossref

Adaptive electrocardiogram (ECG) signal denoising using particle swarm optimization-based non-local means (NLM) filtering

Kiran Jash iD, Nanda Dulal Jana, Swarup Kumar Laha iD

Biomedical Physics & Engineering Express · 2026

DOI: 10.1088/2057-1976/aeb129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2026. Verfasst von Kiran Jash und 2 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Design and Analysis Group, CSIR-Central Mechanical Engineering Research Institute, Durgapur 713209, West Bengal, India. Hauptthemen laut MEDLINE: Electrocardiography, Signal Processing, Computer-Assisted, Arrhythmias, Cardiac. Die Arbeit nennt 44 Literaturangaben. Gefördert von: CSIR-National Laboratories Scheme under the ULIP.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An ECG signal is usually corrupted by AWGN (additive white Gaussian noise), baseline wandering (BW), power line interference (PLI), and motion artifacts (EM), which may impact the reliable diagnosis of arrhythmias. This study proposes a hybrid ECG denoising framework that integrates particle swarm optimization with non-local means filtering to suppress diverse ECG artifacts while preserving signal morphology. In the first experiment, ECG signals from MIT-BIH Arrhythmia Database are artificially contaminated using AWGN and PLI to measure their denoising capability. In the second experiment, real-world BW, muscle artifacts, and electrode EM from the MIT-BIH noise stress test database are used to evaluate the robustness of the proposed framework under practical noise conditions. The proposed method shows improved denoising performance in SNR, PRD, and RMSE for both experiments. Morphology preservation analysis represents minimal distortion of the waveforms and preservation of important ECG characteristics. Furthermore, a one-dimensional ResNet architecture is used for arrhythmia classification, demonstrating good classification performance on the denoised ECG signals with only a minor reduction compared with the noise-free signals. Overall, the proposed framework effectively suppresses diverse ECG artifacts while preserving diagnostically relevant information for arrhythmia classification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographySignal Processing, Computer-AssistedArrhythmias, CardiacParticle Swarm OptimizationHumansArtifactsAlgorithmsSignal-To-Noise Ratio

Stichwörter der Autor:innen

ECG classificationECG denoisingPLInon-local means (NLM)particle swarm optimization (PSO)

Autor:innen und Institutionen

  • Advanced Design and Analysis Group, CSIR-Central Mechanical Engineering Research Institute, Durgapur 713209, West Bengal, India.
  • Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
  • Department of Computer Science and Engineering, National Institute of Technology, Durgapur 713209, West Bengal, India.

ORCID-Profile: Kiran Jash, Swarup Kumar Laha

Förderung

  • CSIR-National Laboratories Scheme under the ULIP

Zitieren

APA

Jash, K., Jana, N. D., & Laha, S. K. (2026). Adaptive electrocardiogram (ECG) signal denoising using particle swarm optimization-based non-local means (NLM) filtering. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/aeb129

Vancouver

Jash K, Jana ND, Laha SK. Adaptive electrocardiogram (ECG) signal denoising using particle swarm optimization-based non-local means (NLM) filtering. Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/aeb129

BibTeX
@article{Jash2026,
  author = {Jash, Kiran and Jana, Nanda Dulal and Laha, Swarup Kumar},
  title = {Adaptive electrocardiogram (ECG) signal denoising using particle swarm optimization-based non-local means (NLM) filtering},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  doi = {10.1088/2057-1976/aeb129}
}
Kostenlos starten →