EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Kinematic Parameters of Normal Hand-to-Mouth Movement in Pediatric Populations: Adaptation of the “Rab Hand-to-Mouth Protocol”

Álvaro Pérez-Somarriba Moreno iD, Rosa María Ortiz-Gutiérrez iD, Patricia Martín-Casas iD, Iñigo Monzón Tobalina, Paula Arias Martínez iD, Ignacio Martínez Caballero, Angélica Guerrero-Blázquez iD, María José Díaz-Arribas iD

Sensors · 23.04.2026 · 26 (9) · 2625

DOI: 10.3390/s26092625 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Sensors, online erschienen am 23.04.2026. Verfasst von Álvaro Pérez-Somarriba Moreno und 7 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral Program in Healthcare, Faculty of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, Plaza de Ramón y Cajal, s/n, 28040…. Hauptthemen laut MEDLINE: Hand. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optoelectronic motion capture systems provide objective and high-resolution measurements of upper limb kinematics. The hand-to-mouth movement is closely related to motor development in children. The “Rab Hand-to-Mouth protocol” (BTS Bioengineering) is widely used; however, its seated configuration constrains elbow posture and may limit the ecological validity of the movement. In this study, we propose a methodological adaptation of the protocol in a standing position to allow a more physiological elbow configuration and to increase the dynamic range of elbow and shoulder motion. The objective was to characterize kinematic patterns of the hand-to-mouth movement in typically developing children aged 4 to 9 years using this adapted setup. This study was designed as a descriptive analysis and does not aim to provide formal validation of the standing protocol against the original seated configuration. An observational study that included 40 children was conducted. Motion data were acquired using eight optoelectronic cameras (sampling frequency: 250 Hz) and 17 reflective markers placed on the trunk and upper limbs. Kinematic patterns and spatiotemporal parameters were computed using dedicated motion analysis software. No significant differences were observed between dominant and non-dominant limbs in spatiotemporal parameters, whereas kinematic differences were minimal and limited to trunk rotation, as identified by Statistical Parametric Mapping (SPM). Some isolated statistically significant associations with age were identified in specific spatiotemporal variables; however, these variables showed low coefficients of determination (R2), indicating limited explanatory power of age. Overall, kinematic parameters did not exhibit consistent age-related patterns. These findings provide preliminary descriptive data for hand-to-mouth kinematics in a standing condition, which may contribute to the future development of assessment protocols. However, the limited sample size and the absence of pathological populations restrict the direct generalization of these findings. Future studies should evaluate the applicability of this approach in clinical cohorts and explore its integration into sensor-based and data-driven models for movement analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HandHumansBiomechanical PhenomenaMotion CaptureChild, PreschoolMovementChildFemaleMaleRange of Motion, ArticularUpper Extremity

Stichwörter der Autor:innen

kinematicsmotor skillspediatricsupper extremity

Autor:innen und Institutionen

  • Doctoral Program in Healthcare, Faculty of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, Plaza de Ramón y Cajal, s/n, 28040 Madrid, Spain.
  • Department of Physiotherapy, Faculty of Nursing, Physiotherapy and Podiatry, Universidad Complutense de Madrid, Plaza de Ramón y Cajal, s/n, 28040 Madrid, Spain.
  • Comprehensive Integral Rehabilitation, Physiotherapy and Neurorehabilitation Research Group, Universidad Complutense de Madrid, Plaza de Ramón y Cajal, s/n, 28040 Madrid, Spain.
  • InPhysio Research Group, Health Research Institute of the Hospital Clínico San Carlos (IdISSC), C/Prof Martín Lagos, s/n, 28040 Madrid, Spain.
  • Clinical Motion Analysis Laboratory, Niño Jesús Children's Hospital, 28009 Madrid, Spain.
  • Research Foundation of the Niño Jesús Children's Hospital, 28009 Madrid, Spain.

ORCID-Profile: Álvaro Pérez-Somarriba Moreno, Rosa María Ortiz-Gutiérrez, Patricia Martín-Casas, Paula Arias Martínez, Angélica Guerrero-Blázquez, María José Díaz-Arribas

Zitieren

APA

Pérez-Somarriba Moreno, Á., Ortiz-Gutiérrez, R. M., Martín-Casas, P., Monzón Tobalina, I., Arias Martínez, P., Martínez Caballero, I., Guerrero-Blázquez, A., & Díaz-Arribas, M. J. (2026). Kinematic Parameters of Normal Hand-to-Mouth Movement in Pediatric Populations: Adaptation of the “Rab Hand-to-Mouth Protocol”. Sensors, 26(9), 2625. https://doi.org/10.3390/s26092625

Vancouver

Pérez-Somarriba Moreno Á, Ortiz-Gutiérrez RM, Martín-Casas P, Monzón Tobalina I, Arias Martínez P, Martínez Caballero I, et al. Kinematic Parameters of Normal Hand-to-Mouth Movement in Pediatric Populations: Adaptation of the “Rab Hand-to-Mouth Protocol”. Sensors. 2026;26(9):2625. doi:10.3390/s26092625

BibTeX
@article{PrezSomarribaMoreno2026,
  author = {Pérez-Somarriba Moreno, Álvaro and Ortiz-Gutiérrez, Rosa María and Martín-Casas, Patricia and Monzón Tobalina, Iñigo and Arias Martínez, Paula and Martínez Caballero, Ignacio and Guerrero-Blázquez, Angélica and Díaz-Arribas, María José},
  title = {Kinematic Parameters of Normal Hand-to-Mouth Movement in Pediatric Populations: Adaptation of the “Rab Hand-to-Mouth Protocol”},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {2625},
  doi = {10.3390/s26092625}
}
Kostenlos starten →