MultiFixRadSoft: A Comprehensive Tool for Primary Relative Radiometric Scale Realization in Radiation Thermometry
Sensors · 17.04.2026 · 26 (8) · 2489
DOI: 10.3390/s26082489 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.04.2026. Verfasst von Mehtap Ertürk und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Metrology Institute, The Scientific and Technological Research Council of Türkiye (TÜBİTAK-UME, Ulusal Metroloji Enstitüsü), Gebze 41470, Tü…. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This paper presents a practical implementation of relative primary radiation thermometry (RPRT) together with MultiFixRadSoft, an open-source software package developed in accordance with the Mise-en-Pratique for the kelvin (MeP-K) for realization of the thermodynamic temperature scale and uncertainty evaluation under the new definition of the kelvin. The software enables realization of temperature scales using ITS-90 metal fixed points as well as metal–carbon and metal–carbide–carbon eutectic high-temperature fixed points (HTFPs) for both radiation thermometers and radiometers. It incorporates automated routines for melting plateau analysis, including determination of the point of inflection, liquidus point, and melting range, together with correction modules for size-of-source effect, detector nonlinearity, emissivity, and temperature drop. Validation is demonstrated through experimental realization using six fixed points (Cu, Fe–C, Co–C, Pd–C, Ru–C, and WC–C) and a linear radiation thermometer. The software also supports ITS-90 extrapolation procedures and flexible calibration schemes (n = 1 to n ≥ 3), with automated Sakuma–Hattori fitting and full uncertainty propagation compliant with MeP-K requirements. The results show excellent agreement with manual analyses and published data, confirming the correctness of the implemented algorithms. By integrating data processing, scale realization, and uncertainty analysis within a unified and transparent framework, MultiFixRadSoft provides a robust and accessible tool for traceable radiometric thermometry, supporting emerging NMIs and industrial laboratories while promoting the wider adoption of primary thermodynamic temperature realization methods.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Metrology Institute, The Scientific and Technological Research Council of Türkiye (TÜBİTAK-UME, Ulusal Metroloji Enstitüsü), Gebze 41470, Türkiye.
- Department of Physics, Gebze Technical University, Gebze 41400, Türkiye.
- RISE-Research Institutes of Sweden, 504 62 Borås, Sweden.
- JV-Justervesenet, 2007 Kjeller, Norway.
ORCID-Profile: Mehtap Ertürk, Mevlüt Karabulut, Ömer Faruk Kadı, Can Gözönünde, Patrik Broberg, Åge Andreas Falnes Olsen, Humbet Nasibli
Zitieren
APA
Ertürk, M., Karabulut, M., Kadı, Ö. F., Gözönünde, C., Broberg, P., Olsen, Å. A. F., & Nasibli, H. (2026). MultiFixRadSoft: A Comprehensive Tool for Primary Relative Radiometric Scale Realization in Radiation Thermometry. Sensors, 26(8), 2489. https://doi.org/10.3390/s26082489
Vancouver
Ertürk M, Karabulut M, Kadı ÖF, Gözönünde C, Broberg P, Olsen ÅAF, et al. MultiFixRadSoft: A Comprehensive Tool for Primary Relative Radiometric Scale Realization in Radiation Thermometry. Sensors. 2026;26(8):2489. doi:10.3390/s26082489
BibTeX
@article{Ertrk2026,
author = {Ertürk, Mehtap and Karabulut, Mevlüt and Kadı, Ömer Faruk and Gözönünde, Can and Broberg, Patrik and Olsen, Åge Andreas Falnes and Nasibli, Humbet},
title = {MultiFixRadSoft: A Comprehensive Tool for Primary Relative Radiometric Scale Realization in Radiation Thermometry},
journal = {Sensors},
year = {2026},
volume = {26},
number = {8},
pages = {2489},
doi = {10.3390/s26082489}
}
EUVIMED