EUVIMEDEUVIMED entdecken
Crossref

Temperature-parameter CRB-guided wavelength selection for multispectral radiation thermometry

Shan Gao, Ming Liu, Hailong Liu, Xinmeng Xiong, Lu Wang, Ying Cui, Tong Wang, Chao Wang

Optics Letters · 01.09.2026 · 51 (17) · 4868

DOI: 10.1364/ol.609687 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Letters, online erschienen am 21.08.2026. Verfasst von Shan Gao und 7 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Precision Measurement Technology and Instruments.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multispectral radiation thermometry (MRT) estimates temperature from several spectral-radiance measurements while compensating for unknown emissivity, but the inversion stability is strongly determined by the wavelength configuration chosen before the inversion. We propose a temperature-parameter Cramér–Rao bound (CRB) guided wavelength-selection method that treats emissivity-model parameters as nuisance parameters and minimizes the CRB component associated with the target temperature. For a power-law emissivity model, an analytical Jacobian is derived for the Fisher information matrix, enabling deterministic evaluation of candidate wavelength sets. Numerical simulations in the 1.1–2.5 μm band show that the predicted temperature CRB agrees with the empirical Monte Carlo temperature-error standard deviation over 27 temperature–emissivity scenarios. Compared with uniform spacing, the proposed CRB-Opt design reduces the average CRB from 3.82% to 2.60%, the RMSE from 3.82% to 2.60%, and the 95th-percentile ARE from 7.59% to 5.23%. Experiments on a pre-oxidized GH4169 nickel-based superalloy further indicate that, under the same calibration and inversion procedure, the CRB-Opt wavelengths reduce the median ARE from 9.85% to 2.50% and suppress the high-error tail relative to uniform spacing. The method provides a temperature-prioritized, physically interpretable, and computationally feasible front-end channel-design criterion for MRT.

Förderung

  • National Natural Science Foundation of China
  • State Key Laboratory of Precision Measurement Technology and Instruments

Zitieren

APA

Gao, S., Liu, M., Liu, H., Xiong, X., Wang, L., Cui, Y., Wang, T., & Wang, C. (2026). Temperature-parameter CRB-guided wavelength selection for multispectral radiation thermometry. Optics Letters, 51(17), 4868. https://doi.org/10.1364/ol.609687

Vancouver

Gao S, Liu M, Liu H, Xiong X, Wang L, Cui Y, et al. Temperature-parameter CRB-guided wavelength selection for multispectral radiation thermometry. Optics Letters. 2026;51(17):4868. doi:10.1364/ol.609687

BibTeX
@article{Gao2026,
  author = {Gao, Shan and Liu, Ming and Liu, Hailong and Xiong, Xinmeng and Wang, Lu and Cui, Ying and Wang, Tong and Wang, Chao},
  title = {Temperature-parameter CRB-guided wavelength selection for multispectral radiation thermometry},
  journal = {Optics Letters},
  year = {2026},
  volume = {51},
  number = {17},
  pages = {4868},
  doi = {10.1364/ol.609687}
}
Kostenlos starten →