Fachartikel in der Zeitschrift Sensors, online erschienen am 10.04.2026. Verfasst von Pavla Šabacká und 10 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a methodology enabling the use of a Pitot probe for static pressure measurement in supersonic flow under severely confined spatial conditions where standard design guidelines cannot be satisfied. In particular, the recommended placement of a static pressure tapping at a distance of 10–20 tube diameters is not feasible; the proposed approach allows for the tapping to be located immediately downstream of the static tube cone. The methodology combines theoretical analysis, experimental measurements, and Computational Fluid Dynamics (CFD) simulations. Experiments were performed using appropriately selected pressure sensors, while detailed simulations in Ansys Fluent (Ansys 2024 R2) included both a high-fidelity probe model and free-stream flow analysis. By comparing experimental and numerical results, a correction coefficient was established based on the free-stream dynamic pressure obtained from CFD. This enables the accurate estimation of static pressure even in non-ideal probe configurations. The measurement error did not exceed 20%, while in most cases, very good agreement between experimental and CFD results was achieved. The main contribution of this paper is the validated methodology, which extends the applicability of Pitot probes to geometrically constrained environments where conventional static pressure measurement techniques cannot be implemented.

Schlagwörter

Stichwörter der Autor:innen

Ansys FluentCFDESEMPitot sensorsaperturedifferentially pumped chamberlow-pressurenozzle

Autor:innen und Institutionen

  • Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.
  • Institute of Scientific Instruments of the CAS, Královopolská 147, 612 64 Brno, Czech Republic.
  • Faculty of AgriSciences, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech Republic.
  • Faculty of Military Technology, University of Defence, Kounicova 65, 662 10 Brno, Czech Republic.

ORCID-Profile: Pavla Šabacká, Jiří Maxa, Robert Bayer, Tomáš Binar, Petr Bača, Vojtěch Hlavička, Jiří Čupera, Jiří Votava, Vojtěch Kumbár, Lenka Dobšáková

Zitieren

APA

Šabacká, P., Maxa, J., Bílek, M., Bayer, R., Binar, T., Bača, P., Hlavička, V., Čupera, J., Votava, J., Kumbár, V., & Dobšáková, L. (2026). Methodology for Static Pressure Measurement Under Confined Spatial Conditions in the Low-Pressure Range. Sensors, 26(8), 2354. https://doi.org/10.3390/s26082354

Vancouver

Šabacká P, Maxa J, Bílek M, Bayer R, Binar T, Bača P, et al. Methodology for Static Pressure Measurement Under Confined Spatial Conditions in the Low-Pressure Range. Sensors. 2026;26(8):2354. doi:10.3390/s26082354

BibTeX
@article{aback2026,
  author = {Šabacká, Pavla and Maxa, Jiří and Bílek, Michal and Bayer, Robert and Binar, Tomáš and Bača, Petr and Hlavička, Vojtěch and Čupera, Jiří and Votava, Jiří and Kumbár, Vojtěch and Dobšáková, Lenka},
  title = {Methodology for Static Pressure Measurement Under Confined Spatial Conditions in the Low-Pressure Range},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {8},
  pages = {2354},
  doi = {10.3390/s26082354}
}
Kostenlos starten →