Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 1-10
DOI: 10.1109/tim.2026.3684657 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yanan Yu und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Open Foundation of the Zhejiang Key Laboratory of Advanced Equipment Manufacturing and Measurement Technology.
Abstract (Originalsprache)
The measurement of the load effect of the shunt resistor under low-pressure conditions is necessary for accurate current measurement, especially in aerospace applications such as power system fault diagnosis and monitoring, where shunt resistors are used for high-current sensing. In this article, a measurement system to evaluate the resistor load effect under low-pressure conditions is designed and experimentally investigated, featuring a resistance measurement module, a pressure control module, and a temperature control module. In the pressure control module, a vacuum pump, an air reservoir, solenoid valves, and pressure sensors are applied to set and maintain various pressure test conditions in a vacuum chamber. The air reservoir is connected in series between the vacuum pump and the vacuum chamber to enhance the stability of pressure control. Experiments are performed to quantify the resistor load effect under low-pressure conditions by measuring its temperature, load, and pressure coefficients. Afterward, the resistance variation with temperature, load power, and pressure is characterized by polynomial models, which is then used to establish a resistance error correction model. Finally, a current compensation scheme is designed to verify the improvement in current measurement accuracy achieved by correction of the shunt resistor load effect under low-pressure conditions. The accuracy of the corrected current measurement is improved by one order of magnitude.
Förderung
- National Key Research and Development Program of China
- Open Foundation of the Zhejiang Key Laboratory of Advanced Equipment Manufacturing and Measurement Technology
Zitieren
APA
Yu, Y., Chen, S., Wang, K., Qian, L., Xu, S., & Fu, Y. (2026). Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions. IEEE Transactions on Instrumentation and Measurement, 75, 1-10. https://doi.org/10.1109/tim.2026.3684657
Vancouver
Yu Y, Chen S, Wang K, Qian L, Xu S, Fu Y. Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions. IEEE Transactions on Instrumentation and Measurement. 2026;75:1-10. doi:10.1109/tim.2026.3684657
BibTeX
@article{Yu2026,
author = {Yu, Yanan and Chen, Shengshi and Wang, Kai and Qian, Lushuai and Xu, Suan and Fu, Yaqiong},
title = {Measurement and Correction of the Resistor Load Effect Under Low-Pressure Conditions},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {1--10},
doi = {10.1109/tim.2026.3684657}
}
EUVIMED