An Evaluation Method for Partial Discharge in Generator Stator Bar Insulation Based on Fiber-Optic Acoustic Detection
Sensors · 25.03.2026 · 26 (7) · 2053
DOI: 10.3390/s26072053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 25.03.2026. Verfasst von Jianlin Hu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Chongqing University, Chongqing 400044, China. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Partial-discharge (PD) monitoring is essential for assessing the insulation condition of generator stator bars. Conventional methods are susceptible to electromagnetic interference and are difficult to deploy in confined stator geometries. Fiber-optic acoustic detection technology offers strong immunity to electromagnetic interference and is suitable for the narrow and high-interference environment of stator bars, but it cannot directly provide discharge magnitude information. Therefore, in this study, fiber-optic acoustic detection technology was employed to acquire partial discharge acoustic signals from stator bars, and a mandrel-type fiber-optic acoustic sensor was developed, with PD tests performed on full-scale stator bars with internal defects. Meanwhile, considering the complex temporal characteristics of PD acoustic signals, a hybrid neural network—Transformer–convolutional neural network–long short-term memory (Transformer–CNN–LSTM)—was constructed for long-term time-series modeling to establish the mapping between acoustic signals and discharge magnitude intervals. The results indicate that fiber-optic acoustic detection enables sensitive and stable detection of weak PD acoustic signals. Phase-resolved PD (PRPD) patterns from the proposed system align with the discharge characteristics of internal defects, with the acoustic signal showing a phase lag relative to the electrical PD signal. The hybrid model achieved an overall interval estimation accuracy of 96.6%, outperforming CNN and CNN-LSTM models, with accuracies of 100% and 99.4% for discharge magnitude intervals below 100 pC and above 2000 pC, respectively.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
ORCID-Profile: Jianlin Hu, Jiapeng Yang, Wentao Luo
Zitieren
APA
Hu, J., Yang, J., Qin, P., Jiang, X., & Luo, W. (2026). An Evaluation Method for Partial Discharge in Generator Stator Bar Insulation Based on Fiber-Optic Acoustic Detection. Sensors, 26(7), 2053. https://doi.org/10.3390/s26072053
Vancouver
Hu J, Yang J, Qin P, Jiang X, Luo W. An Evaluation Method for Partial Discharge in Generator Stator Bar Insulation Based on Fiber-Optic Acoustic Detection. Sensors. 2026;26(7):2053. doi:10.3390/s26072053
BibTeX
@article{Hu2026,
author = {Hu, Jianlin and Yang, Jiapeng and Qin, Peiyu and Jiang, Xingliang and Luo, Wentao},
title = {An Evaluation Method for Partial Discharge in Generator Stator Bar Insulation Based on Fiber-Optic Acoustic Detection},
journal = {Sensors},
year = {2026},
volume = {26},
number = {7},
pages = {2053},
doi = {10.3390/s26072053}
}