EUVIMEDEUVIMED entdecken
Crossref

Partial Discharge in Stator Winding Under Harmonic Voltage Superimposed on Generator Voltage

Shin Nakamura, Takashi Kuraishi, Satoru Miyazaki

IEEE Transactions on Dielectrics and Electrical Insulation · 2025-12 · 32 (6) · 3532-3539

DOI: 10.1109/tdei.2025.3557791 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Dielectrics and Electrical Insulation, 2025-12. Verfasst von Shin Nakamura und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Partial discharge (PD) magnitude and phase-resolved PD (PRPD) patterns are key indicators for diagnosing stator winding insulation. Nonlinear loads in power systems induce harmonic voltages that can alter the PD characteristics, and this may subsequently affect insulation diagnostics. This study investigates the impact of harmonic voltage superimposition on the PD behavior in stator windings. We measure the PDs in the coil bar extracted from the stator winding under harmonic voltages superimposed on the ac voltage. We analyze the effects of the harmonic order and ratio on the PD characteristics. We also conduct PD measurements on an actual hydrogenerator exposed to a high-order harmonic voltage. The findings show that while harmonic superimposition can alter PRPD patterns, its effect on the PD magnitude is negligible. Therefore, when using PD-based insulation diagnostics, special attention should be given to the impact of harmonic voltages, particularly when PRPD patterns are used to identify insulation defects.

Zitieren

APA

Nakamura, S., Kuraishi, T., & Miyazaki, S. (2025). Partial Discharge in Stator Winding Under Harmonic Voltage Superimposed on Generator Voltage. IEEE Transactions on Dielectrics and Electrical Insulation, 32(6), 3532-3539. https://doi.org/10.1109/tdei.2025.3557791

Vancouver

Nakamura S, Kuraishi T, Miyazaki S. Partial Discharge in Stator Winding Under Harmonic Voltage Superimposed on Generator Voltage. IEEE Transactions on Dielectrics and Electrical Insulation. 2025;32(6):3532-3539. doi:10.1109/tdei.2025.3557791

BibTeX
@article{Nakamura2025,
  author = {Nakamura, Shin and Kuraishi, Takashi and Miyazaki, Satoru},
  title = {Partial Discharge in Stator Winding Under Harmonic Voltage Superimposed on Generator Voltage},
  journal = {IEEE Transactions on Dielectrics and Electrical Insulation},
  year = {2025},
  volume = {32},
  number = {6},
  pages = {3532--3539},
  doi = {10.1109/tdei.2025.3557791}
}
Kostenlos starten →