Validity, Reliability and Interpretability of an IMU-Based System to Measure 3D Lower Limb Kinematics of Patients with Heterogeneous Gait Disorders
Sensors · 10.03.2026 · 26 (6) · 1746
DOI: 10.3390/s26061746 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 10.03.2026. Verfasst von Lena Carcreff und 5 weiteren Autor:innen. Beteiligte Einrichtung: Kinesiology Laboratory, Geneva University Hospitals and Geneva University, 1205 Geneva, Switzerland. Hauptthemen laut MEDLINE: Lower Extremity, Gait, Gait Analysis, Gait Disorders, Neurologic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innosuisse - Swiss Innovation Agency, INNOSUISSE—Swiss Innovation Agency.
Abstract (Originalsprache)
Inertial measurement units (IMUs) represent a promising alternative to optoelectronic systems for estimating gait kinematics in less resource-intensive laboratories. However, evidence regarding the clinical interpretability of IMU-based gait analysis in pathological populations remains limited. This study aimed to evaluate the concurrent validity, reliability, and interpretability of an IMU-based method for computing 3D lower limb kinematics in asymptomatic and pathological populations. Fifty-five participants, including asymptomatic individuals (AS, n = 15), patients with cerebral palsy (CP, n = 15), and individuals with various motor disorders (OMD, n = 25), were assessed using a 7-IMU system and an optoelectronic system. Validity was quantified using root mean square error (RMSE), centered RMSE, and Pearson correlation coefficients (CCs) across 11 commonly reported lower limb kinematic outcomes. Reliability was assessed using intraclass correlation coefficients (ICCs), and interpretability was examined by comparing Gait Profile Scores (GPS) derived from both systems. Mean RMSE values were 7.1° (AS), 9.8° (CP), and 9.3° (OMD), with centered RMSE values below 3.2°. The correlation between IMU- and optoelectronic-based kinematics was good to excellent (mean CC = 0.76). Reliability ranged from moderate to excellent, and GPS showed moderate agreement between systems (CC = 0.42). These findings support the clinical validity, reliability, and interpretability of IMU-based gait kinematics across heterogeneous gait disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kinesiology Laboratory, Geneva University Hospitals and Geneva University, 1205 Geneva, Switzerland.
- Department of Physical Medicine and Rehabilitation, University Hospital of Angers, 49100 Angers, France.
- MindMaze, 1006 Lausanne, Switzerland.
- Center of Research on Skeletal Muscle and Movement, Geneva University Hospitals and Geneva University, 1205 Geneva, Switzerland.
ORCID-Profile: Lena Carcreff, Gautier Grouvel, Stéphane Armand
Förderung
- Innosuisse - Swiss Innovation Agency
- INNOSUISSE—Swiss Innovation Agency
Zitieren
APA
Carcreff, L., Payen, G., Grouvel, G., Cardoso-Fonseca, M., Massé, F., & Armand, S. (2026). Validity, Reliability and Interpretability of an IMU-Based System to Measure 3D Lower Limb Kinematics of Patients with Heterogeneous Gait Disorders. Sensors, 26(6), 1746. https://doi.org/10.3390/s26061746
Vancouver
Carcreff L, Payen G, Grouvel G, Cardoso-Fonseca M, Massé F, Armand S. Validity, Reliability and Interpretability of an IMU-Based System to Measure 3D Lower Limb Kinematics of Patients with Heterogeneous Gait Disorders. Sensors. 2026;26(6):1746. doi:10.3390/s26061746
BibTeX
@article{Carcreff2026,
author = {Carcreff, Lena and Payen, Gabriel and Grouvel, Gautier and Cardoso-Fonseca, Mickael and Massé, Fabien and Armand, Stéphane},
title = {Validity, Reliability and Interpretability of an IMU-Based System to Measure 3D Lower Limb Kinematics of Patients with Heterogeneous Gait Disorders},