Assessing Time–Frequency Analysis Methods for Non-Stationary EMG Bursts: Application to an Animal Model of Parkinson’s Disease
Sensors · 07.03.2026 · 26 (5) · 1688
DOI: 10.3390/s26051688 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 07.03.2026. Verfasst von Fernando Daniel Farfán und 3 weiteren Autor:innen. Beteiligte Einrichtung: Neuroscience and Applied Technologies Laboratory (LINTEC), Bioengineering Department, Faculty of Exact Sciences and Technology (FACET), National Univ…. Hauptthemen laut MEDLINE: Electromyography, Parkinson Disease. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PIUNT E701, Argentinian “Universidad Nacional de Tucumán”, Argentinian “Consejo Nacional de Investigaciones Científicas y Técnicas”.
Abstract (Originalsprache)
Time–frequency (TF) characterization of electromyographic (EMG) bursts is essential for accurately assessing muscle function, particularly when the signals exhibit a high degree of nonstationarity. In this exploratory study, we investigated the temporal dynamics of the spectral components associated with short-latency EMG bursts using several TF analysis techniques. Specifically, we compared the performance and interpretability of spectrograms obtained via the short-time Fourier transform (STFT), the continuous wavelet transform (CWT), and noise-assisted multivariate empirical mode decomposition (NA-MEMD), applied to EMG signals recorded from the biceps femoris muscle of freely moving rats in an animal model of Parkinson’s disease, acquired using chronically implanted bipolar electrodes during treadmill locomotion. For each method, we evaluated its effectiveness in capturing transient variations in frequency content, the stability of extracted features across bursts, and the extent to which these features reflect physiologically meaningful aspects of muscle activation. The results show that TF approaches reveal complementary information about burst structure; NA-MEMD provides greater adaptability to nonlinear and nonstationary components, whereas STFT- and CWT-based representations offer more controlled and comparable analyses. Overall, these findings highlight the value of TF analysis as a methodological tool for evaluating muscle function and provide a solid foundation for selecting analytical strategies in studies where EMG bursts exhibit complex and highly variable spectral profiles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuroscience and Applied Technologies Laboratory (LINTEC), Bioengineering Department, Faculty of Exact Sciences and Technology (FACET), National University of Tucuman, Superior Institute of Biological Research (INSIBIO)…
- Institute of Bioengineering, Universidad Miguel Hernández of Elche, 03202 Elche, Spain.
- Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain.
ORCID-Profile: Fernando Daniel Farfán, Ana Lía Albarracín, Leonardo Ariel Cano, Eduardo Fernández
Förderung
- PIUNT E701
- Argentinian “Universidad Nacional de Tucumán”
- Argentinian “Consejo Nacional de Investigaciones Científicas y Técnicas”
- Argentinian “Instituto Superior de Investigaciones Biológicas”
Zitieren
APA
Farfán, F. D., Albarracín, A. L., Cano, L. A., & Fernández, E. (2026). Assessing Time–Frequency Analysis Methods for Non-Stationary EMG Bursts: Application to an Animal Model of Parkinson’s Disease. Sensors, 26(5), 1688. https://doi.org/10.3390/s26051688
Vancouver
Farfán FD, Albarracín AL, Cano LA, Fernández E. Assessing Time–Frequency Analysis Methods for Non-Stationary EMG Bursts: Application to an Animal Model of Parkinson’s Disease. Sensors. 2026;26(5):1688. doi:10.3390/s26051688
BibTeX
@article{Farfn2026,
author = {Farfán, Fernando Daniel and Albarracín, Ana Lía and Cano, Leonardo Ariel and Fernández, Eduardo},
title = {Assessing Time–Frequency Analysis Methods for Non-Stationary EMG Bursts: Application to an Animal Model of Parkinson’s Disease},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1688},
doi = {10.3390/s26051688}
}
EUVIMED