Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Lander De Waele und 2 weiteren Autor:innen. Beteiligte Einrichtung: Movement Control and Neuroplasticity Research Group, KU Leuven, 3001 Leuven, Belgium. Hauptthemen laut MEDLINE: Photogrammetry, Smartphone, Prosthesis Design, Artificial Limbs. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate modeling of residual limb geometry is essential for prosthetic socket design, yet current scanning techniques can be costly, operator-dependent, or impractical for repeated clinical use. This study presents a fully automated, low-cost photogrammetry workflow capable of generating metrically accurate 3D models of lower-limb residual limbs using video and still images acquired with a standard smartphone or a full-frame digital camera. The pipeline integrates adaptive frame selection, deep learning-based background removal, robust metric scaling via ArUco markers, and open-source Structure-from-Motion and Multi-View Stereo reconstruction, requiring no manual post-processing or proprietary software. Accuracy and repeatability were evaluated using four 3D-printed limb phantoms and high-resolution CT-derived meshes as ground truth. Smartphone video and full-frame camera acquisitions achieved sub-millimeter surface accuracy, volume and perimeter errors within ±1%, and high inter-session repeatability, all within clinically accepted thresholds for prosthetic socket fabrication. In contrast, smartphone still-photo reconstructions showed larger deviations and reduced stability. Acquisition time was under five minutes, and complete reconstruction required approximately 1 h and 30 min. These results demonstrate that smartphone video-based photogrammetry provides a practical, scalable, and clinically viable alternative for residual limb modeling, particularly in resource-constrained or remote care settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetrySmartphoneProsthesis DesignArtificial LimbsHumansImaging, Three-DimensionalImage Processing, Computer-Assisted

Stichwörter der Autor:innen

3D reconstructionamputationdeep learning segmentationdigital prostheticslimb scanningmarker-based scalingphotogrammetryprostheticsresidual limbsocket design

Autor:innen und Institutionen

  • Movement Control and Neuroplasticity Research Group, KU Leuven, 3001 Leuven, Belgium.
  • Leuven Brain Institute (LBI), KU Leuven, 3000 Leuven, Belgium.

ORCID-Profile: Jolien Gooijers, Dante Mantini

Zitieren

APA

De Waele, L., Gooijers, J., & Mantini, D. (2026). Smartphone-Based Automated Photogrammetry for Reconstruction of Residual Limb Models in Prosthetic Design. Sensors. https://doi.org/10.3390/s26041251

Vancouver

De Waele L, Gooijers J, Mantini D. Smartphone-Based Automated Photogrammetry for Reconstruction of Residual Limb Models in Prosthetic Design. Sensors. 2026. doi:10.3390/s26041251

BibTeX
@article{DeWaele2026,
  author = {De Waele, Lander and Gooijers, Jolien and Mantini, Dante},
  title = {Smartphone-Based Automated Photogrammetry for Reconstruction of Residual Limb Models in Prosthetic Design},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26041251}
}