Smartphone scanning is a reliable and accurate alternative to contemporary residual limb measurement techniques
PLOS ONE · 02.12.2024 · 19 (12) · e0313542
DOI: 10.1371/journal.pone.0313542 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 02.12.2024. Verfasst von Sam Walters und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Bath, Bath, Somerset, United Kingdom. Hauptthemen laut MEDLINE: Smartphone. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Monitoring the volume and shape of residual limbs post-amputation is necessary to achieve optimal socket fit and determine overall limb health, yet contemporary clinical measurement techniques show high variance between measures. Three-dimensional scanning presents an opportunity for improved accuracy and reliability of residual limb measurements, however, three-dimensional scanners remain prohibitively expensive. A cost-effective alternative is the use of software that can utilise the photographs of modern smartphone cameras to create geometrically accurate scans. Whilst several studies have investigated the potential of privately developed photogrammetry algorithms for capturing residual limbs with clinical accuracy, none to the authors knowledge have explored commercially available software to do the same. Three applications were tested, namely Polycam, Luma, and Meshroom, to determine if they could produce clinically acceptable results. Scans of ten residual limbs were created using both smartphone technology and a reference structured-light scanner (Artec EVA), against which the validity and reliability of the resulting limb models were assessed using the Bland-Altman method and Intraclass Correlation Coefficient, respectively. Polycam and Luma achieved both Pearson Coefficients and Intraclass Correlation Coefficients of 0.999, and Coefficients of Variation of 1.1% and 1.4%, respectively. Volume reliability coefficients were 58.3 ml and 70.0 ml respectively for Polycam and Luma, whereas Meshroom failed to meet any of the criteria for clinical suitability, with a repeatability coefficient of 790.3 ml. Both Polycam and Luma exhibit sufficient accuracy and reliability to be considered for clinical volume measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, University of Bath, Bath, Somerset, United Kingdom.
- Bath Institute for the Augmented Human, University of Bath, Bath, Somerset, United Kingdom.
- School of Health and Society, University of Salford, Manchester, Greater Manchester, United Kingdom.
- Department for Health, University of Bath, Bath, Somerset, United Kingdom.
- Centre for the Analysis of Motion, Entertainment Research Applications (CAMERA), University of Bath, Bath, Somerset, United Kingdom.
- Department of Engineering, King's College London, London, Greater London, United Kingdom.
ORCID-Profile: Sam Walters, Benjamin Metcalfe, Nicola Y Bailey
Förderung
- Engineering and Physical Sciences Research Council
Zitieren
APA
Walters, S., Metcalfe, B., Twiste, M., Seminati, E., & Bailey, N. Y. (2024). Smartphone scanning is a reliable and accurate alternative to contemporary residual limb measurement techniques. PLOS ONE, 19(12), e0313542. https://doi.org/10.1371/journal.pone.0313542
Vancouver
Walters S, Metcalfe B, Twiste M, Seminati E, Bailey NY. Smartphone scanning is a reliable and accurate alternative to contemporary residual limb measurement techniques. PLOS ONE. 2024;19(12):e0313542. doi:10.1371/journal.pone.0313542
BibTeX
@article{Walters2024,
author = {Walters, Sam and Metcalfe, Benjamin and Twiste, Martin and Seminati, Elena and Bailey, Nicola Y},
title = {Smartphone scanning is a reliable and accurate alternative to contemporary residual limb measurement techniques},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {12},
pages = {e0313542},
doi = {10.1371/journal.pone.0313542}
}