Smartphone-Based Markerless Motion Capture for Spatiotemporal Gait Assessment: Applied Within-Session Reliability and Comparability of OpenCap Versus OptoGait
Sensors · 13.02.2026 · 26 (4) · 1234
DOI: 10.3390/s26041234 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 13.02.2026. Verfasst von Christopher James Keating und 2 weiteren Autor:innen. Beteiligte Einrichtung: Facultad de Deportes, Universidad Católica San Antonio de Murcia, 30107 Guadalupe, Spain. Hauptthemen laut MEDLINE: Motion Capture, Gait, Smartphone, Gait Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective gait assessment is increasingly needed beyond specialized laboratories, and 3D markerless motion capture is emerging as a viable option; however, evidence regarding its applied repeatability and practical use for spatiotemporal gait outcomes in scalable clinical and field settings remains limited. This study evaluated the applied repeatability and practical comparability of OpenCap (camera-based; CM) versus a commonly accepted photoelectric walkway (OptoGait; OPT). Thirty-nine healthy adults completed three 10-m overground trials at self-selected speed. CM parameters were derived from OpenCap’s Advanced Overground Gait Analysis. Within-device reliability was good-to-excellent for gait speed, stride length, and cadence (ICC (3,1) = 0.734–0.920 OPT; 0.791–0.917 CM) and excellent when averaging three trials (ICC (3,3) = 0.892–0.972 OPT; 0.919–0.971 CM); double support showed lower reliability (ICC (3,1) = 0.527 OPT; 0.647 CM). Between devices, CM showed higher mean speed (+0.110 m/s), stride length (+0.127 m), and double support (+3.17% of the gait cycle), while cadence was very similar (−0.59 spm). Correlations were high for speed (r = 0.951), stride length (r = 0.864), and cadence (r = 0.983) but moderate for double support (r = 0.405); absolute-agreement ICCs were highest for cadence (0.980) and lowest for double support (0.271). OpenCap provides reliable within-session estimates for key spatiotemporal measures, but systematic bias indicates it should be used consistently as a standalone tool rather than interchangeably with OptoGait without device-specific correction or reference values.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Facultad de Deportes, Universidad Católica San Antonio de Murcia, 30107 Guadalupe, Spain.
- Department of Human Sciences and Promotion of the Quality of Life, San Raffaele Open University of Rome, 00166 Rome, Italy.
- Department of Neurosciences, Biomedicine and Movement, University of Verona, 37134 Verona, Italy.
ORCID-Profile: Christopher James Keating, Matteo Vitarelli, Domenico Cherubini
Zitieren
APA
Keating, C. J., Vitarelli, M., & Cherubini, D. (2026). Smartphone-Based Markerless Motion Capture for Spatiotemporal Gait Assessment: Applied Within-Session Reliability and Comparability of OpenCap Versus OptoGait. Sensors, 26(4), 1234. https://doi.org/10.3390/s26041234
Vancouver
Keating CJ, Vitarelli M, Cherubini D. Smartphone-Based Markerless Motion Capture for Spatiotemporal Gait Assessment: Applied Within-Session Reliability and Comparability of OpenCap Versus OptoGait. Sensors. 2026;26(4):1234. doi:10.3390/s26041234
BibTeX
@article{Keating2026,
author = {Keating, Christopher James and Vitarelli, Matteo and Cherubini, Domenico},
title = {Smartphone-Based Markerless Motion Capture for Spatiotemporal Gait Assessment: Applied Within-Session Reliability and Comparability of OpenCap Versus OptoGait},
journal = {Sensors},
year = {2026},
volume = {26},
number = {4},
pages = {1234},
doi = {10.3390/s26041234}
}