A Dual-Mode Near-Infrared Optical Probe and Monte Carlo Framework for Functional Monitoring of Rheumatoid Arthritis: Addressing Diagnostic Ambiguity and Skin Tone Robustness
Sensors · 2026
DOI: 10.3390/s26041179 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Parmveer Atwal und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC V3T 0A3, Canada. Hauptthemen laut MEDLINE: Arthritis, Rheumatoid, Skin. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Michael Smith Health Research BC.
Abstract (Originalsprache)
Current diagnostic modalities for rheumatoid arthritis (RA), such as Magnetic Resonance Imaging (MRI) and ultrasound (US), excel at visualizing structural pathology but are either resource-intensive or often limited to morphological assessment. In this work, we present the design and technical validation of a low-cost continuous-wave near-infrared (NIR) dual-mode optical probe for functional monitoring of joint inflammation. Unlike superficial imaging, NIR light penetrates approximately 3–5 cm and is tissue and wavelength dependent, enabling trans-illumination of the synovial volume. The system combines reflectance and transmission geometries to resolve the ambiguity between disease presence and disease severity. To validate the diagnostic logic, we employed mcxyzn Monte Carlo (MC) simulations to model the optical signature of RA progression from early onset to EULAR-OMERACT grade 2 pannus hypertrophy on a simplified finger model, based on several tissue models in the literature and supported by physical measurements on a multilayer silicone phantom and in vivo signal verification on human volunteers. Our results demonstrate a distinct functional dichotomy: reflectance geometry serves as a binary discriminator of synovial turbidity onset, while transmission flux serves as a monotonic proxy for pannus volume, exhibiting a quantifiable signal decay consistent with the Beer–Lambert law. Signal verification on a subject with confirmed RA pathology demonstrated a significant increase in the effective attenuation coefficient (µeff ~ 0.59 mm−1) compared to the healthy baseline (µeff ~ 0.47 mm−1). Furthermore, simulation analysis revealed a critical “metric inversion” in darker skin phenotypes (Fitzpatrick V–VI), where the standard beam-broadening signature of inflammation is artificially suppressed by epidermal absorption. We conclude that while transmission flux remains a robust grading metric across diverse skin tones, morphological beam-shape metrics are not robust, particularly in high-absorption populations. By targeting the hemodynamic precursors of structural damage, this dual-mode probe design offers a potential pathway for longitudinal, quantitative monitoring of disease activity at the point of care, while the systematic use of the Monte Carlo framework provides insight into the measurement geometry most suitable for a given clinical endpoint, whether that be detecting the presence or severity of rheumatoid arthritis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC V3T 0A3, Canada.
- Department of Medical Physics, BC Cancer-Abbotsford, Abbotsford, BC V2S 0C2, Canada.
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Michael Smith Health Research BC
Zitieren
APA
Atwal, P., McWilliams, R., Ramaseshen, R., & Golnaraghi, F. (2026). A Dual-Mode Near-Infrared Optical Probe and Monte Carlo Framework for Functional Monitoring of Rheumatoid Arthritis: Addressing Diagnostic Ambiguity and Skin Tone Robustness. Sensors. https://doi.org/10.3390/s26041179
Vancouver
Atwal P, McWilliams R, Ramaseshen R, Golnaraghi F. A Dual-Mode Near-Infrared Optical Probe and Monte Carlo Framework for Functional Monitoring of Rheumatoid Arthritis: Addressing Diagnostic Ambiguity and Skin Tone Robustness. Sensors. 2026. doi:10.3390/s26041179
BibTeX
@article{Atwal2026,
author = {Atwal, Parmveer and McWilliams, Ryley and Ramaseshen, Ramani and Golnaraghi, Farid},
title = {A Dual-Mode Near-Infrared Optical Probe and Monte Carlo Framework for Functional Monitoring of Rheumatoid Arthritis: Addressing Diagnostic Ambiguity and Skin Tone Robustness},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26041179}
}
EUVIMED