EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mechanical Stability of Amorphous Silicon Thin-Film Devices on Polyimide for Flexible Sensor Platforms

Giulia Petrucci iD, Fabio Cappelli iD, Martina Baldini, Francesca Costantini iD, Augusto Nascetti iD, Giampiero de Cesare iD, Domenico Caputo iD, Nicola Lovecchio iD

Sensors · 04.02.2026 · 26 (3) · 1026

DOI: 10.3390/s26031026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 04.02.2026. Verfasst von Giulia Petrucci und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sapienza University of Rome, Sapienza University Research Project 2024.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydrogenated amorphous silicon (a-Si:H) is a mature thin-film technology for large-area devices and thin-film sensors, and its low-temperature growth via Plasma-Enhanced Chemical Vapor Deposition (PECVD) makes it particularly suitable for biomedical flexible and wearable platforms. However, the reliable integration of a-Si:H sensors on polymer substrates requires a quantitative assessment of their electrical stability under mechanical stress, since bending-induced variations may affect sensor accuracy. In this work, we provide a quantitative, direction-dependent evaluation of the static-bending robustness of both single-doped a-Si:H layers and complete p-i-n junction stacks on polyimide (Kapton®), thereby linking material-level strain sensitivity to device-level functionality. First, n- and p-doped a-Si:H layers were deposited on 50 µm thick Kapton® and then structured as two-terminal thin-film resistors to enable resistivity extraction under bending conditions. Electrical measurements were performed on multiple samples, with the current path oriented either parallel (longitudinal) or perpendicular (transverse) to the bending axis, and resistance profiles were determined as a function of bending radius. While n-type layers exhibited limited and mostly gradual variations, p-type layers showed a stronger sensitivity to mechanical stress, with a critical-radius behavior under transverse bending and a more progressive evolution in the longitudinal one. This directional response identifies a practical bending condition under which doped layers, particularly p-type films, are more susceptible to strain-induced degradation. Subsequently, a linear array of a-Si:H p-i-n sensors was fabricated on Kapton® substrates with two different thicknesses (25 and 50 µm thick) and characterized under identical bending conditions. Despite the increased strain sensitivity observed in the single-layers, the p-i-n diodes preserved their rectifying behavior down to the smallest radius tested. Indeed, across the investigated radii, the reverse current at −0.5 V remained consistent, confirming stable junction operation under bending. Only minor differences, related to substrate thickness, were observed in the reverse current and in the high-injection regime. Overall, these results demonstrate the mechanical robustness of stacked a-Si:H junctions on polyimide and support their use as sensors for wearable biosensing architectures. By establishing a quantitative, orientation-aware stability benchmark under static bending, this study supports the design of reliable a-Si:H flexible sensor platforms for curved and wearable surfaces.

Schlagwörter

Stichwörter der Autor:innen

flexible electronicshydrogenated amorphous silicon sensorsmechanical bendingp-i-n diodep-i-n sensorpolyimide (Kapton®)wearable sensors

Autor:innen und Institutionen

  • Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy.
  • School of Aerospace Engineering, Sapienza University of Rome, Via Salaria 851, 00138 Rome, Italy.
  • Research Centre for Plant Protection and Certification, Council for Agricultural Research and Economics (CREA-DC), Via Carlo Giuseppe Bertero 22, 00156 Rome, Italy.

ORCID-Profile: Giulia Petrucci, Fabio Cappelli, Francesca Costantini, Augusto Nascetti, Giampiero de Cesare, Domenico Caputo, Nicola Lovecchio

Förderung

  • Sapienza University of Rome
  • Sapienza University Research Project 2024

Zitieren

APA

Petrucci, G., Cappelli, F., Baldini, M., Costantini, F., Nascetti, A., de Cesare, G., Caputo, D., & Lovecchio, N. (2026). Mechanical Stability of Amorphous Silicon Thin-Film Devices on Polyimide for Flexible Sensor Platforms. Sensors, 26(3), 1026. https://doi.org/10.3390/s26031026

Vancouver

Petrucci G, Cappelli F, Baldini M, Costantini F, Nascetti A, de Cesare G, et al. Mechanical Stability of Amorphous Silicon Thin-Film Devices on Polyimide for Flexible Sensor Platforms. Sensors. 2026;26(3):1026. doi:10.3390/s26031026

BibTeX
@article{Petrucci2026,
  author = {Petrucci, Giulia and Cappelli, Fabio and Baldini, Martina and Costantini, Francesca and Nascetti, Augusto and de Cesare, Giampiero and Caputo, Domenico and Lovecchio, Nicola},
  title = {Mechanical Stability of Amorphous Silicon Thin-Film Devices on Polyimide for Flexible Sensor Platforms},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {3},
  pages = {1026},
  doi = {10.3390/s26031026}
}
Kostenlos starten →