Real-Time Wearable sEMG Onset Detection and Phase Discrimination of Sit-to-Stand Movement via a Compact Dual-Channel DD-CNN
Sensors · 2026
DOI: 10.3390/s26144375 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Meernah Mohammed Alabdullah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia. Hauptthemen laut MEDLINE: Electromyography, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Ministry of Education of the Kingdom of Saudi Arabia and facilitated by the Saudi Cultural Bureau.
Abstract (Originalsprache)
Repeated sit-to-stand and stand-to-sit transitions load the knee extensors and may contribute to work-related musculoskeletal disorders. Reducing this load requires assistive devices and monitoring of knee function, which depend on real-time onset/offset detection and direction-aware classification of each transition. However, no prior wearable surface electromyographic system has delivered this capability for real-time. This study presents a deep learning method that computes both onset/offset detection and direction discrimination of sit-to-stand and stand-to-sit in a developed wearable surface electromyographic system in real-time. Two ESP32-S3 nodes and a hub record from the vastus lateralis and vastus medialis and run a per-burst convolutional detector, while the hub runs a dual-branch classifier with seventeen handcrafted features. Trained offline on the public Gait120 dataset, the networks are deployed unchanged with embedded-firmware parity to the MATLAB reference. Under leave-one-subject-out evaluation on Gait120, the offline classifier separated each transition with 99.6% accuracy and the detector achieved 96.6% completeness. In real-time recordings from thirty healthy adults, the system retained 85.6% classification and 82.0% detection accuracy, with ≈100 ms latency and a 618 KB network footprint. Results show that a low-power wearable delivers combined detection and phase discrimination in real-time, supporting the potential application in assistive-device control and knee-joint monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering Department, Imam Abdulrahman Bin Faisal University, Dammam 31451, Saudi Arabia.
- School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK.
- School of Biomedical Sciences, University of Leeds, Leeds LS2 9JT, UK.
- Modern College of Engineering, Henan Normal University, Xinxiang 453007, China.
ORCID-Profile: Meernah Mohammed Alabdullah, Aiqin Liu, Yiliu Tu, Sheng Quan Xie
Förderung
- Ministry of Education
- Ministry of Education of the Kingdom of Saudi Arabia and facilitated by the Saudi Cultural Bureau
Zitieren
APA
Alabdullah, M. M., Liu, A., Tu, Y., & Xie, S. Q. (2026). Real-Time Wearable sEMG Onset Detection and Phase Discrimination of Sit-to-Stand Movement via a Compact Dual-Channel DD-CNN. Sensors. https://doi.org/10.3390/s26144375
Vancouver
Alabdullah MM, Liu A, Tu Y, Xie SQ. Real-Time Wearable sEMG Onset Detection and Phase Discrimination of Sit-to-Stand Movement via a Compact Dual-Channel DD-CNN. Sensors. 2026. doi:10.3390/s26144375
BibTeX
@article{Alabdullah2026,
author = {Alabdullah, Meernah Mohammed and Liu, Aiqin and Tu, Yiliu and Xie, Sheng Quan},
title = {Real-Time Wearable sEMG Onset Detection and Phase Discrimination of Sit-to-Stand Movement via a Compact Dual-Channel DD-CNN},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26144375}
}
EUVIMED