EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimizing Surface Functionalization for Aptameric Graphene Nanosensors in Undiluted Physiological Media

Wenting Dai, Ziran Wang, Shifeng Yu, Kechun Wen, Yucheng Yang iD, Qiao Lin

Sensors · 2026

DOI: 10.3390/s26020744 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Wenting Dai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA. Hauptthemen laut MEDLINE: Graphite, Aptamers, Nucleotide, Biosensing Techniques, Nanotechnology. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDDK NIH HHS, National Institute of Allergy and Infectious Diseases, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the optimization of surface modification for aptameric graphene nanosensors for the measurement of biomarkers in undiluted physiological media. In these sensors, graphene transduces the binding between an aptamer and the intended target biomarker into a measurable signal while being coated with a polyethylene glycol (PEG) nanolayer to minimize nonspecific adsorption of matrix molecules. We perform a systematic study of the aptamer and PEG attachment schemes and parameters, including the impact of the serial or parallel PEG–aptamer attachment scheme, PEG molecular weight and surface density, and aptamer surface density on the sensor behavior, such as the responsivity to biomarker concentration changes, and importantly, they are used for operation in physiological media and have the ability to reject nonspecific binding to interfering molecules. We then use the understanding from this parametric study to identify graphene nanosensor designs that are optimally functionalized with PEG and aptamers to be strongly responsive to target biomarkers and effectively reduce nonspecific adsorption of interferents, thereby enabling sensitive and specific biomarker measurements in undiluted physiological media. The experimental results show that nanosensors that were optimized via serial modification with 5000 Da PEG at 15 mM and a 94 nt DNA aptamer at 500 nM allowed specific measurement of C-reactive protein (CRP) in undiluted human serum with a limit of detection (LOD) down to 27 pM, representing an up to 1000-fold improvement compared to previously reported CRP measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteAptamers, NucleotideBiosensing TechniquesNanotechnologyHumansPolyethylene GlycolsC-Reactive ProteinSurface PropertiesBiomarkersCarbon Nanomaterials

Stichwörter der Autor:innen

C-reactive proteinaptamerbiosensorgraphene field-effect transistorpolyethylene glycolundiluted physiological media

Substanzen

GraphiteAptamers, NucleotidePolyethylene GlycolsC-Reactive ProteinBiomarkers

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.

ORCID-Profile: Yucheng Yang

Förderung

  • NIDDK NIH HHS
  • National Institute of Allergy and Infectious Diseases
  • NIH HHS
  • NIBIB NIH HHS
  • NIGMS NIH HHS
  • NIAID NIH HHS
  • NCI NIH HHS
  • National Institutes of Health

Zitieren

APA

Dai, W., Wang, Z., Yu, S., Wen, K., Yang, Y., & Lin, Q. (2026). Optimizing Surface Functionalization for Aptameric Graphene Nanosensors in Undiluted Physiological Media. Sensors. https://doi.org/10.3390/s26020744

Vancouver

Dai W, Wang Z, Yu S, Wen K, Yang Y, Lin Q. Optimizing Surface Functionalization for Aptameric Graphene Nanosensors in Undiluted Physiological Media. Sensors. 2026. doi:10.3390/s26020744

BibTeX
@article{Dai2026,
  author = {Dai, Wenting and Wang, Ziran and Yu, Shifeng and Wen, Kechun and Yang, Yucheng and Lin, Qiao},
  title = {Optimizing Surface Functionalization for Aptameric Graphene Nanosensors in Undiluted Physiological Media},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26020744}
}
Kostenlos starten →