Improved Pressure Sensing Performance of Self-Powered Electrochemical Pressure Sensor Using a Simple Electrode Coplanar Structure
Sensors · 21.01.2026 · 26 (2) · 699
DOI: 10.3390/s26020699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.01.2026. Verfasst von Yixue Han und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Scie…. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Fund for Distinguished Young Scholars, Natural Science Foundation of China, Sichuan Innovation Research Group Project.
Abstract (Originalsprache)
In recent years, electrochemical pressure (ECP) sensors with self-powered and both dynamic and static pressure detection capabilities have received widespread attention. To improve pressure sensing performances while reducing the thickness of conventional sandwich structure ECP sensors, we propose an ECP sensor with a simple electrode coplanar structure. Specifically, it consists of Cu/Zn foil electrodes and LiCl/polyvinyl alcohol (PVA) modified filter paper. Among them, the Cu/Zn coplanar electrodes are used for redox reactions, the LiCl provides conductive ions, and the PVA is used to provide a humid environment to promote the ionization and conduction of LiCl. The rough surface microstructure of the filter paper is used to enhance the pressure sensing performances of the sensor. The results show that the ECP sensor with an electrode coplanar structure can spontaneously output current in the pressure range of 0.4–100 kPa, with sensitivities of 0.273 kPa−1 (0.6–20 kPa) and 0.036 kPa−1 (20–100 kPa). Specifically, compared to ECP sensors with a sandwich structure, it has a wider response range and higher sensitivity. Through the current response, morphological characterizations, and redox reactions, the pressure sensing mechanism is elucidated. Furthermore, the proposed ECP sensor can be used for respiratory state recognition combined with machine learning. This research provides a new approach for developing a high-performance ECP sensor with a simple electrode coplanar structure.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu 611731, China.
ORCID-Profile: Zaihua Duan, Zhen Yuan
Förderung
- National Science Fund for Distinguished Young Scholars
- Natural Science Foundation of China
- Sichuan Innovation Research Group Project
Zitieren
APA
Han, Y., Duan, Z., Wang, Y., Chen, W., Liu, D., Yuan, Z., Jiang, Y., & Tai, H. (2026). Improved Pressure Sensing Performance of Self-Powered Electrochemical Pressure Sensor Using a Simple Electrode Coplanar Structure. Sensors, 26(2), 699. https://doi.org/10.3390/s26020699
Vancouver
Han Y, Duan Z, Wang Y, Chen W, Liu D, Yuan Z, et al. Improved Pressure Sensing Performance of Self-Powered Electrochemical Pressure Sensor Using a Simple Electrode Coplanar Structure. Sensors. 2026;26(2):699. doi:10.3390/s26020699
BibTeX
@article{Han2026,
author = {Han, Yixue and Duan, Zaihua and Wang, Yi and Chen, Weidong and Liu, Di and Yuan, Zhen and Jiang, Yadong and Tai, Huiling},
title = {Improved Pressure Sensing Performance of Self-Powered Electrochemical Pressure Sensor Using a Simple Electrode Coplanar Structure},
journal = {Sensors},
year = {2026},
volume = {26},
number = {2},
pages = {699},
doi = {10.3390/s26020699}
}
EUVIMED