Observing Mixed Chemical Reactions at the Positive Electrode in the High-Performance Self-Powered Electrochemical Humidity Sensor

Mingxiang Zhang, Zaihua Duan iD, Zhen Yuan, Yadong Jiang, Huiling Tai iD

ACS Nano · 17.12.2024 · 18 (50) · 34158-34170

DOI: 10.1021/acsnano.4c10432 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Nano, online erschienen am 03.12.2024. Verfasst von Mingxiang Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Scie…. Die Arbeit wurde bisher 121-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Science Fund for Distinguished Young Scholars, National Natural Science Foundation of China, Sichuan Provincial Science and Technology Support Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical humidity (ECH) sensors that integrate power generation and humidity sensing have attracted great research attention in recent years. However, the design of high-performance ECH sensors faces many challenges. Namely, the working mechanism of the ECH sensors is still controversial, and related self-powered applications have not been well implemented. To overcome these limitations, this study constructs an ECH sensor with high power-generation and humidity-sensing performance using the KCl/carbon black/halloysite nanotubes (KCl/CB/HNTs) as a humidity-sensing electrolyte. The proposed ECH sensor has a wide humidity-sensing response of 10.9%-91.5% relative humidity (RH), and a single ECH sensor can output 1.46 V with a maximum power of 133.2 μW at 91.5% RH. Particularly, the unprecedented mixed chemical reactions at the positive electrode, including the hydrogen evolution reaction and oxygen reduction reaction, are analyzed using multiple characterization and testing techniques. The analysis results provide solid experimental evidence for the current controversial working mechanism of ECH sensors. Due to the advantage of high-power generation, the proposed ECH sensor can be used for self-powered humidity detection. This study provides a valuable reference for improving the power generation of ECH sensors and solid evidence for clarifying their working mechanism, which could be beneficial for guiding the future development of ECH sensors.

Schlagwörter

Stichwörter der Autor:innen

humidity sensormixed chemical reactionmultifunctional applicationself-powered sensorworking mechanism analysis

Autor:innen und Institutionen

  • State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu 611731, P. R. China.

ORCID-Profile: Zaihua Duan, Huiling Tai

Förderung

  • National Science Fund for Distinguished Young Scholars
  • National Natural Science Foundation of China
  • Sichuan Provincial Science and Technology Support Program

Zitieren

APA

Zhang, M., Duan, Z., Yuan, Z., Jiang, Y., & Tai, H. (2024). Observing Mixed Chemical Reactions at the Positive Electrode in the High-Performance Self-Powered Electrochemical Humidity Sensor. ACS Nano, 18(50), 34158-34170. https://doi.org/10.1021/acsnano.4c10432

Vancouver

Zhang M, Duan Z, Yuan Z, Jiang Y, Tai H. Observing Mixed Chemical Reactions at the Positive Electrode in the High-Performance Self-Powered Electrochemical Humidity Sensor. ACS Nano. 2024;18(50):34158-34170. doi:10.1021/acsnano.4c10432

BibTeX
@article{Zhang2024,
  author = {Zhang, Mingxiang and Duan, Zaihua and Yuan, Zhen and Jiang, Yadong and Tai, Huiling},
  title = {Observing Mixed Chemical Reactions at the Positive Electrode in the High-Performance Self-Powered Electrochemical Humidity Sensor},
  journal = {ACS Nano},
  year = {2024},
  volume = {18},
  number = {50},
  pages = {34158--34170},
  doi = {10.1021/acsnano.4c10432}
}