Atrial Fibrillation Detection from At-Rest PPG Signals Using an SDOF-TF Method
Sensors · 08.01.2026 · 26 (2) · 416
DOI: 10.3390/s26020416 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 08.01.2026. Verfasst von Mamun Hasan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Signal Processing, Computer-Assisted, Photoplethysmography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
At-rest PPG signals have been explored for detecting atrial fibrillation (AF), yet current signal-processing techniques do not achieve perfect accuracy even under low-motion artifact (MA) conditions. This study evaluates the effectiveness of a single-degree-of-freedom time–frequency (SDOF-TF) method in analyzing at-rest PPG signals for AF detection. The method leverages the influence of MA on the instant parameters of each harmonic, which is identified using an SDOF model in which the tissue–contact–sensor (TCS) stack is treated as an SDOF system. In this model, MA induces baseline drift and time-varying system parameters. The SDOF-TF method enables the quantification and removal of MA and noise, allowing for the accurate extraction of the arterial pulse waveform, heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM). Using data from the MIMIC PERform AF dataset, the method achieved 100% accuracy in distinguishing AF from non-AF cases based on three features: (1) RM, (2) HRV derived from instant frequency and instant initial phase, and (3) standard deviation of HR across harmonics. Compared with non-AF, the RM for each harmonic was increased by AF. RM exhibited an increasing trend with harmonic order in non-AF subjects, whereas this trend was diminished in AF subjects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA.
ORCID-Profile: Mamun Hasan, Zhili Hao
Zitieren
APA
Hasan, M., & Hao, Z. (2026). Atrial Fibrillation Detection from At-Rest PPG Signals Using an SDOF-TF Method. Sensors, 26(2), 416. https://doi.org/10.3390/s26020416
Vancouver
Hasan M, Hao Z. Atrial Fibrillation Detection from At-Rest PPG Signals Using an SDOF-TF Method. Sensors. 2026;26(2):416. doi:10.3390/s26020416
BibTeX
@article{Hasan2026,
author = {Hasan, Mamun and Hao, Zhili},
title = {Atrial Fibrillation Detection from At-Rest PPG Signals Using an SDOF-TF Method},
journal = {Sensors},
year = {2026},
volume = {26},
number = {2},
pages = {416},
doi = {10.3390/s26020416}
}
EUVIMED