An ML-Based Approach to Reconstruct Heart Rate from PPG in Presence of Motion Artifacts
Biosensors · 2023
DOI: 10.3390/bios13070718 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von José María Vicente-Samper und 6 weiteren Autor:innen. Beteiligte Einrichtung: Neuroengineering Biomedical Group, Institute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain. Hauptthemen laut MEDLINE: Photoplethysmography, Autism Spectrum Disorder. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Spanish Research State Agency.
Abstract (Originalsprache)
The heart rate (HR) is a widely used clinical variable that provides important information on a physical user’s state. One of the most commonly used methods for ambulatory HR monitoring is photoplethysmography (PPG). The PPG signal retrieved from wearable devices positioned on the user’s wrist can be corrupted when the user is performing tasks involving the motion of the arms, wrist, and fingers. In these cases, the obtained HR is altered as well. This problem increases when trying to monitor people with autism spectrum disorder (ASD), who are very reluctant to use foreign bodies, notably hindering the adequate attachment of the device to the user. This work presents a machine learning approach to reconstruct the user’s HR signal using an own monitoring wristband especially developed for people with ASD. An experiment is carried out, with users performing different daily life activities in order to build a dataset with the measured signals from the monitoring wristband. From these data, an algorithm is applied to obtain a reliable HR value when these people are performing skill improvement activities where intensive wrist movement may corrupt the PPG.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuroengineering Biomedical Group, Institute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.
- Unit of Advanced Robotics and Human-Centred Technologies, Department of Engineering, Università Campus Bio-Medico di Roma, 00128 Rome, Italy.
- Department of Materials Science, Optics and Electronic Technology, Miguel Hernández University of Elche, 03202 Elche, Spain.
- Institute of Bioengineering, Miguel Hernández University of Elche, 03202 Elche, Spain.
ORCID-Profile: José María Vicente-Samper, Christian Tamantini, Ernesto Ávila-Navarro, Miguel Ángel De La Casa-Lillo, Loredana Zollo, José María Sabater-Navarro, Francesca Cordella
Förderung
- Spanish Research State Agency
Zitieren
APA
Vicente-Samper, J. M., Tamantini, C., Ávila-Navarro, E., De La Casa-Lillo, M. Á., Zollo, L., Sabater-Navarro, J. M., & Cordella, F. (2023). An ML-Based Approach to Reconstruct Heart Rate from PPG in Presence of Motion Artifacts. Biosensors. https://doi.org/10.3390/bios13070718
Vancouver
Vicente-Samper JM, Tamantini C, Ávila-Navarro E, De La Casa-Lillo MÁ, Zollo L, Sabater-Navarro JM, et al. An ML-Based Approach to Reconstruct Heart Rate from PPG in Presence of Motion Artifacts. Biosensors. 2023. doi:10.3390/bios13070718
BibTeX
@article{VicenteSamper2023,
author = {Vicente-Samper, José María and Tamantini, Christian and Ávila-Navarro, Ernesto and De La Casa-Lillo, Miguel Ángel and Zollo, Loredana and Sabater-Navarro, José María and Cordella, Francesca},
title = {An ML-Based Approach to Reconstruct Heart Rate from PPG in Presence of Motion Artifacts},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13070718}
}
EUVIMED