EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals

Qianheng Yin, Yixiong Chen, Lan Lin iD, Dongdong Wang, Shen Sun iD

Sensors · 2026

DOI: 10.3390/s26010345 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Qianheng Yin und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Life Sciences, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing 100124, China. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure Determination, Blood Pressure, Capillaries. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the impact of capillary refill time (CRT) modulation on photoplethysmography (PPG) signals for improved non-invasive continuous blood pressure (CBP) estimation. Data from 21 healthy participants were collected, applying a standardized 9 N pressure for 15 s to induce CRT during 6-min sessions. PPG signals were segmented into 252 paired 30-s intervals (CRT-modulated and standard). Three machine learning models—ResNetCNN, LSTM, and Transformer—were validated using leave-one-subject-out (LOSO) and non-LOSO methods. CRT modulation significantly enhanced accuracy across all models. ResNetCNN showed substantial improvements, reducing mean absolute error (MAE) by up to 35.6% and mean absolute percentage error (MAPE) by up to 40.6%. LSTM and Transformer models also achieved notable accuracy gains. All models met the Association for the Advancement of Medical Instrumentation (AAMI) criteria (mean error < 5 mmHg; standard deviation < 8 mmHg). The findings suggest CRT modulation’s strong potential to improve wearable CBP monitoring, especially in resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyBlood Pressure DeterminationBlood PressureCapillariesHumansMaleMachine LearningFemaleAdultSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

artificial intelligenceblood pressurecapillary refill timemachine learningphotoplethysmography

Autor:innen und Institutionen

  • College of Chemistry and Life Sciences, Beijing University of Technology, No. 100 Pingleyuan, Chaoyang District, Beijing 100124, China.
  • Beijing Science and Technology Project Manager Management Corporation Ltd., Beijing 100084, China.

ORCID-Profile: Lan Lin, Shen Sun

Zitieren

APA

Yin, Q., Chen, Y., Lin, L., Wang, D., & Sun, S. (2026). Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals. Sensors. https://doi.org/10.3390/s26010345

Vancouver

Yin Q, Chen Y, Lin L, Wang D, Sun S. Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals. Sensors. 2026. doi:10.3390/s26010345

BibTeX
@article{Yin2026,
  author = {Yin, Qianheng and Chen, Yixiong and Lin, Lan and Wang, Dongdong and Sun, Shen},
  title = {Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26010345}
}
Kostenlos starten →