EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Photoplethysmography-based non-invasive blood pressure monitoring via ensemble model and imbalanced dataset processing

Qianyu Liu, Chaojie Yang, Sen Yang, Chiew Foong Kwong, Jing Wang, Ning Zhou

Physical and Engineering Sciences in Medicine · 2024

DOI: 10.1007/s13246-024-01445-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Qianyu Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Science and Engineering, NingboTech University, Ningbo, China. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoplethysmography, a widely embraced tool for non-invasive blood pressure (BP) monitoring, has demonstrated potential in BP prediction, especially when machine learning techniques are involved. However, predictions with a singular model often fall short in terms of accuracy. In order to counter this issue, we propose an innovative ensemble model that utilizes Light Gradient Boosting Machine (LightGBM) as the base estimator for predicting systolic and diastolic BP. This study included 115 women and 104 men, with experimental results indicating mean absolute errors of 5.63 mmHg and 9.36 mmHg for diastolic and systolic BP, in line with level B and C standards set by the British Hypertension Society. Additionally, our research confronts data imbalance in medical research which can detrimentally affect classification. Here we demonstrate an effective use for the Synthetic Minority Over-sampling Technique (SMOTE) with three nearest neighbors for handling moderate imbalanced datasets. The application of this method outperformed other methods in the field, achieving an F1 score of 81.6% and an AUC value of 0.895, emphasizing the potential value of SMOTE for addressing imbalanced datasets in medical research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyBlood PressureHumansFemaleMaleBlood Pressure DeterminationMachine LearningMiddle AgedAlgorithmsAdult

Stichwörter der Autor:innen

Data imbalanceHypertensionMachine learningPPG

Autor:innen und Institutionen

  • School of Information Science and Engineering, NingboTech University, Ningbo, China.
  • Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China. ssycy5@nottingham.ac.uk.
  • Department of Electrical and Electronic Engineering, University of Nottingham, Nottingham, UK. ssycy5@nottingham.ac.uk.
  • Department of Electrical and Electronic Engineering, University of Nottingham Ningbo, Ningbo, China.
  • Next Generation Internet of Everything (NGIoE) Laboratory, University of Nottingham Ningbo, Ningbo, China.
  • School of Civil Engineering and Architecture, NingboTech University, Ningbo, China.

Zitieren

APA

Liu, Q., Yang, C., Yang, S., Kwong, C. F., Wang, J., & Zhou, N. (2024). Photoplethysmography-based non-invasive blood pressure monitoring via ensemble model and imbalanced dataset processing. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01445-6

Vancouver

Liu Q, Yang C, Yang S, Kwong CF, Wang J, Zhou N. Photoplethysmography-based non-invasive blood pressure monitoring via ensemble model and imbalanced dataset processing. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01445-6

BibTeX
@article{Liu2024,
  author = {Liu, Qianyu and Yang, Chaojie and Yang, Sen and Kwong, Chiew Foong and Wang, Jing and Zhou, Ning},
  title = {Photoplethysmography-based non-invasive blood pressure monitoring via ensemble model and imbalanced dataset processing},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  doi = {10.1007/s13246-024-01445-6}
}
Kostenlos starten →