Quantitative Assessment of Biomechanical Deviations in Hybrid III Dummy Response Caused by Accessory Lumbar Supports
Sensors · 2025
DOI: 10.3390/s25247647 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Wanda Górniak. Beteiligte Einrichtung: Laboratory of Vehicle Dynamics and Safety, Department of Automotive Engineering, Mechanical Faculty, Wrocław University of Science and Technology, Na…. Hauptthemen laut MEDLINE: Accidents, Traffic, Lumbosacral Region. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre, National Science Centre (NCN), Poland.
Abstract (Originalsprache)
Rear-end collisions remain a significant category of road accidents, despite widespread passive safety systems. Although modern seats are designed to reduce injury risk, the influence of accessory lumbar supports on passenger safety is still insufficiently investigated. This study analyzes the biomechanical response of a Hybrid III 50th percentile dummy on a vehicle seat fitted with various lumbar support types, compared to a reference configuration. Tests were conducted on a sled bench, simulating impacts of varying energy using crash pulses of 10 g, 15 g, and 20 g, for each tested lumbar support configuration in carefully controlled laboratory conditions. A key element of the procedure was analyzing changes in head and chest acceleration waveforms relative to results obtained for the reference seat. To quantitatively assess discrepancies between signals, the Root Mean Square Error (RMSE) and the CORA (CORrelation and Analysis) objective rating method were applied. These tools enabled precise separation of amplitude changes from phase shifts arising from different system dynamics. The results show that additional equipment elements modify dummy–seat interaction, with the extent of biomechanical response changes also depending on crash pulse value. This indicates that ergonomic supports are not biomechanically neutral and should be considered in comprehensive safety analyses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of Vehicle Dynamics and Safety, Department of Automotive Engineering, Mechanical Faculty, Wrocław University of Science and Technology, Na Grobli 13, 50-421 Wrocław, Poland.
ORCID-Profile: Wanda Górniak
Förderung
- National Science Centre
- National Science Centre (NCN), Poland
Zitieren
APA
Górniak, W. (2025). Quantitative Assessment of Biomechanical Deviations in Hybrid III Dummy Response Caused by Accessory Lumbar Supports. Sensors. https://doi.org/10.3390/s25247647
Vancouver
Górniak W. Quantitative Assessment of Biomechanical Deviations in Hybrid III Dummy Response Caused by Accessory Lumbar Supports. Sensors. 2025. doi:10.3390/s25247647
BibTeX
@article{Grniak2025,
author = {Górniak, Wanda},
title = {Quantitative Assessment of Biomechanical Deviations in Hybrid III Dummy Response Caused by Accessory Lumbar Supports},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25247647}
}