EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors

Maurício A P Papi iD, Victor G Scheidweiler, Sandra de Melo Cassemiro, Leni C Akcelrud, Marcio F Bergamini iD, Luiz Humberto Marcolino-Junior

Sensors · 2025

DOI: 10.3390/s25247535 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Maurício A P Papi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba 81531-980, PR, Brazil. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Financial Services Company.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

ITIC’s superior electron-accepting capacity and efficient oxygen reduction motivated the design of a sensor to enhance sensitivity, selectivity, and stability over conventional oxygen-dependent or fullerene-based systems. As oxygen acts as the terminal reagent in enzymatic glucose oxidation, we developed an ITIC-mediated glucose oxidase (GOx) biosensor on glassy carbon (GCE) and screen-printed carbon electrodes (SPCE). ITIC, a non-fullerene organic semiconductor, was drop-cast onto the electrode to catalyze oxygen reduction, followed by GOx immobilization in a chitosan matrix. Scanning electron microscopy (SEM) confirmed uniform, ultrathin coatings without significant morphological changes upon ITIC and GOx deposition. Electrochemical studies (cyclic (CV) and differential pulse voltammetry (DPV)) revealed a distinct ITIC reduction peak at –0.7 V (vs. Ag/AgCl) and a glucose-dependent current decrease, consistent with mediated electron transfer during enzymatic oxidation. Under optimized conditions, the GCE-based biosensor showed a sensitivity of 10.7 μA L mmol−1, a linear dynamic range (LDR) of 0.10–1.00 mmol L−1, and detection (LOD)/quantification (LOQ) limits of 0.02 and 0.06 mmol L−1, respectively. The SPCE device displayed sensitivity (3.8 μA L mmol−1) and maintained excellent linearity (R2 > 0.99) with LOD and LOQ of 0.05 and 0.16 mmol L−1. Both platforms showed good precision (RSD < 5%) and reliable recovery in deproteinized plasma and artificial tears (90–104%). The superior performance of the GCE is attributed to higher ITIC loading, faster electron transfer, and reduced background current, while the SPCE offers a low-cost, disposable format with sufficient analytical performance for point-of-care glucose monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGlucoseElectrochemical TechniquesGlucose OxidaseOxidation-ReductionSemiconductorsFullerenesElectrodesEnzymes, ImmobilizedCarbonOxygenLimit of DetectionChitosan

Stichwörter der Autor:innen

electrochemical biosensingglucose analysisnon-fullerene mediatorportable devicesscreen-printed electrodes

Substanzen

Glucose OxidaseGlucoseFullerenesEnzymes, ImmobilizedCarbonOxygenChitosan

Autor:innen und Institutionen

  • Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba 81531-980, PR, Brazil.
  • Paulo Scarpa Polymer Laboratory (LaPPS), Departamento de Química, Universidade Federal do Paraná (UFPR), Curitiba 81531-980, PR, Brazil.

ORCID-Profile: Maurício A P Papi, Marcio F Bergamini

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Financial Services Company
  • Fundação Araucária
  • Brazilian Institute of Science and Technology: INCT-Nanocarbon and INCT-Nanomaterials for Life

Zitieren

APA

Papi, M. A. P., Scheidweiler, V. G., Cassemiro, S. M., Akcelrud, L. C., Bergamini, M. F., & Marcolino-Junior, L. H. (2025). Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors. Sensors. https://doi.org/10.3390/s25247535

Vancouver

Papi MAP, Scheidweiler VG, Cassemiro SM, Akcelrud LC, Bergamini MF, Marcolino-Junior LH. Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors. Sensors. 2025. doi:10.3390/s25247535

BibTeX
@article{Papi2025,
  author = {Papi, Maurício A P and Scheidweiler, Victor G and Cassemiro, Sandra de Melo and Akcelrud, Leni C and Bergamini, Marcio F and Marcolino-Junior, Luiz Humberto},
  title = {Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25247535}
}
Kostenlos starten →