Enhancing Signal and Network Integrity: Evaluating BCG Artifact Removal Techniques in Simultaneous EEG-fMRI Data
Sensors · 2025
DOI: 10.3390/s25227036 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Perihan Gülşah Gülhan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Electronics Engineering, Institute of Science, Selcuk University, Konya 42130, Turkey. Hauptthemen laut MEDLINE: Electroencephalography, Magnetic Resonance Imaging, Brain, Ballistocardiography. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Simultaneous Electroencephalography (EEG) and functional Magnetic Resonance Imaging (fMRI) provide a powerful framework for investigating brain dynamics; however, ballistocardiogram (BCG) artifacts in EEG compromise signal quality and limit the assessment of brain connectivity. This study evaluated three widely used artifact removal methods—Average Artifact Subtraction (AAS), Optimal Basis Set (OBS), and Independent Component Analysis (ICA)—together with two hybrid approaches (AAS + ICA and OBS + ICA). Unlike previous studies that focused solely on signal-level metrics, we adopted a holistic framework that combined signal quality indicators with graph-theoretical analysis of EEG-fMRI connectivity in static and dynamic contexts. The results show that AAS provides the best signal quality, whereas OBS better preserves structural similarity. ICA, although weaker in terms of signal metrics, demonstrates sensitivity to frequency-specific patterns in dynamic graphs. Hybrid methods yield benefits, with OBS + ICA producing the lowest p-values across frequency band pairs (e.g., theta–beta and delta–gamma), particularly in dynamic graphs. Topological analyses revealed that artifact removal significantly affected network structure, with dynamic analyses showing more pronounced frequency-specific effects than static analyses. High-frequency bands, such as beta and gamma, exhibit stronger differentiation under dynamic conditions. Overall, this study offers new insights into the relationship between artifact removal and brain network integrity, emphasizing the need for multimodal and frequency-sensitive evaluation strategies. The findings guide preprocessing decisions in EEG-fMRI studies and clarify how methodological choices shape the interpretation of brain connectivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Electronics Engineering, Institute of Science, Selcuk University, Konya 42130, Turkey.
- Department of Optoelectronics and Electro-Optic Technologies, Akyurt Vocational School, Ankara University, Ankara 06935, Turkey.
- Department of Biomedical Engineering, Selcuk University, Konya 42075, Turkey.
ORCID-Profile: Perihan Gülşah Gülhan, Güzin Özmen
Zitieren
APA
Gülhan, P. G., & Özmen, G. (2025). Enhancing Signal and Network Integrity: Evaluating BCG Artifact Removal Techniques in Simultaneous EEG-fMRI Data. Sensors. https://doi.org/10.3390/s25227036
Vancouver
Gülhan PG, Özmen G. Enhancing Signal and Network Integrity: Evaluating BCG Artifact Removal Techniques in Simultaneous EEG-fMRI Data. Sensors. 2025. doi:10.3390/s25227036
BibTeX
@article{Glhan2025,
author = {Gülhan, Perihan Gülşah and Özmen, Güzin},
title = {Enhancing Signal and Network Integrity: Evaluating BCG Artifact Removal Techniques in Simultaneous EEG-fMRI Data},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25227036}
}
EUVIMED