Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yumei Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Key Laboratory of High Dynamic Navigation Technology, Beijing Information Science Technology University, Beijing 100096, China. Hauptthemen laut MEDLINE: Spine, Robotics, Scoliosis, Robotic Surgical Procedures. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing Natural Science Foundation, Beijing New-star Plan of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetically controlled spinal growing rods, used for treating early-onset scoliosis (EOS), face a critical clinical limitation: insufficient distraction force. Compounding this issue is the inherent inability to directly monitor the mechanical output of such implants in vivo, which challenges their safety and efficacy. To overcome these limitations, optimizing the rotor’s maximum torque is essential. Furthermore, defining the “continuous rotation domain” establishes a vital safety boundary for stable operation, preventing loss of synchronization and loss of control, thus safeguarding the efficacy of future clinical control strategies. In this study, a transient finite element magnetic field simulation model of a circumferentially distributed permanent magnet–rotor system was established using ANSYS Maxwell (2024). The effects of the clamp angle between the driving magnets and the rotor, the number of pole pairs, the rotor’s outer diameter, and the rotational speed of the driving magnets on the rotor’s maximum torque were systematically analyzed, and the optimized continuous rotation domain of the rotor was determined. The results indicated that when the clamp angle was set at 120°, the number of pole pairs was one, the rotor outer diameter was 8 mm, the rotor achieved its maximum torque and exhibited the largest continuous rotation domain, while the rotational speed of the driving magnets had no effect on maximum torque. Following optimization, the maximum torque of the simulation increased by 201% compared with the pre-optimization condition, and the continuous rotation domain was significantly enlarged. To validate the simulation, a rotor torque measurement setup incorporating a torque sensor was constructed. Experimental results showed that the maximum torque improved from 30 N·mm before optimization to 90 N·mm after optimization, while the driving magnets maintained stable rotation throughout the process. Furthermore, a spinal growing rod test platform equipped with a pressure sensor was developed to evaluate actuator performance and measure the maximum distraction force. The optimized growing rod achieved a peak distraction force of 413 N, nearly double that of the commercial MAGEC system, which reached only 208 N. The simulation and experimental methodologies established in this study not only optimizes the device’s performance but also provides a viable pathway for in vivo performance prediction and monitoring, addressing a critical need in smart implantable technology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SpineRoboticsScoliosisRobotic Surgical ProceduresTorqueHumansEquipment DesignMagnetic FieldsFinite Element Analysis

Stichwörter der Autor:innen

early-onset scoliosiselectromagnetic actuatorspinal growing rodtorque optimization

Autor:innen und Institutionen

  • Beijing Key Laboratory of High Dynamic Navigation Technology, Beijing Information Science Technology University, Beijing 100096, China.
  • Key Laboratory of Modern Measurement Control Technology, Ministry of Education, Beijing Information Science Technology University, Beijing 100096, China.
  • Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
  • State Key Laboratory of Tribology in Advanced Equipment, Tsinghua University, Beijing 100084, China.
  • Beijing Key Laboratory of Transformative High-End Manufacturing Equipment and Technology, Tsinghua University, Beijing 100084, China.
  • Department of Pediatric Orthopedics, Beijing Jishuitan Hospital, Beijing 100035, China.

ORCID-Profile: Zhenguo Nie

Förderung

  • Beijing Natural Science Foundation
  • Beijing New-star Plan of Science and Technology

Zitieren

APA

Li, Y., Li, Z., Lu, D., Peng, T., Chen, Y., Fu, G., Nie, Z., & Wei, F. (2025). Enhancing Torque Output for a Magnetic Actuation System for Robotic Spinal Distraction. Sensors. https://doi.org/10.3390/s25206497

Vancouver

Li Y, Li Z, Lu D, Peng T, Chen Y, Fu G, et al. Enhancing Torque Output for a Magnetic Actuation System for Robotic Spinal Distraction. Sensors. 2025. doi:10.3390/s25206497

BibTeX
@article{Li2025,
  author = {Li, Yumei and Li, Zikang and Lu, Ding and Peng, Tairan and Chen, Yunzhi and Fu, Gang and Nie, Zhenguo and Wei, Fangyuan},
  title = {Enhancing Torque Output for a Magnetic Actuation System for Robotic Spinal Distraction},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25206497}
}
Kostenlos starten →