EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring

Catharina Nina Van Oost iD, Federica Masci, Adelien Malisse iD, An-Marie Schyvens, Brent Peters iD, Hélène Dirix iD, Veerle Ross iD, Geert Wets, An Neven iD, Johan Verbraecken iD, Jean-Marie Aerts iD

Sensors · 2025

DOI: 10.3390/s25206319 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Sensors, 2025. Verfasst von Catharina Nina Van Oost und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biosystems, KU Leuven, 3000 Leuven, Belgium. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Flanders Innovation & Entrepreneurship - VLAIO, Flanders Innovation & Entrepreneurship—VLAIO.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable devices are increasingly used for health and stress monitoring, yet their accuracy under dynamic, real-world conditions remains uncertain. This study validated the heart rate measurement accuracy of one chest-worn device (Zephyr BioHarness 3.0), a research-grade wrist-worn device (EmbracePlus), and five commercial wrist-worn wearable devices (Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, and Withings Scanwatch) against a 12-lead ECG using a 20 min protocol simulating real-life dynamics, including rest and varied-intensity walking. Device performance was evaluated across the full protocol and during transient states, defined as periods of rapid heart rate change. Accuracy and agreement were evaluated across per-second, 10 s, and 60 s resolutions. The Zephyr device showed a strong performance during all dynamic conditions. Among the wrist-worn devices, the Fitbit Charge 5 and Sense 2 showed the highest accuracy overall, while the Garmin Vivosmart 4 demonstrated greater stability during transitions. The WHOOP 4.0, Withings Scanwatch, and EmbracePlus devices performed acceptably during steady-state conditions, but were less accurate during transitions. Performance notably declined across all wrist-worn devices during transient states, with motion onset and large step changes in heart rate exacerbating measurement errors. Larger averaging windows improved accuracy by smoothing variability. The findings underscore that wrist-worn wearable devices may be better suited for average and trend heart rate monitoring rather than capturing acute dynamics. However, the Garmin and Fitbit devices showed suitable when requiring moderate accuracy during dynamic conditions. These results highlight the importance of context-specific validation and informed device selection to ensure effective use in health and stress-related applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesHumansMonitoring, PhysiologicMaleAdultFemaleElectrocardiographyWalking

Stichwörter der Autor:innen

dynamic conditionsheart ratestress monitoringtransient statesvalidation studywearable devices

Autor:innen und Institutionen

  • Department of Biosystems, KU Leuven, 3000 Leuven, Belgium.
  • Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, 2650 Edegem, Belgium.
  • Laboratory of Experimental Medicine and Pediatrics, University of Antwerp, 2000 Wilrijk, Belgium.
  • Transportation Research Institute (IMOB), School of Transportation Sciences, Hasselt University, 3500 Hasselt, Belgium.
  • Faresa, Evidence-Based Psychological Centre, 3570 Hasselt, Belgium.

ORCID-Profile: Catharina Nina Van Oost, Adelien Malisse, Brent Peters, Hélène Dirix, Veerle Ross, An Neven, Johan Verbraecken, Jean-Marie Aerts

Förderung

  • Flanders Innovation & Entrepreneurship - VLAIO
  • Flanders Innovation & Entrepreneurship—VLAIO

Zitieren

APA

Van Oost, C. N., Masci, F., Malisse, A., Schyvens, A. M., Peters, B., Dirix, H., Ross, V., Wets, G., Neven, A., Verbraecken, J., & Aerts, J. M. (2025). Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring. Sensors. https://doi.org/10.3390/s25206319

Vancouver

Van Oost CN, Masci F, Malisse A, Schyvens AM, Peters B, Dirix H, et al. Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring. Sensors. 2025. doi:10.3390/s25206319

BibTeX
@article{VanOost2025,
  author = {Van Oost, Catharina Nina and Masci, Federica and Malisse, Adelien and Schyvens, An-Marie and Peters, Brent and Dirix, Hélène and Ross, Veerle and Wets, Geert and Neven, An and Verbraecken, Johan and Aerts, Jean-Marie},
  title = {Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25206319}
}
Kostenlos starten →