Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram

Nina Sviridova iD, Sora Okazaki

Sensors · 2025

DOI: 10.3390/s25196232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Nina Sviridova und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intelligent Systems, Tokyo City University, 1-28-1 Tamazutsumi, Setagaya-ku, Tokyo 158-8557, Japan. Hauptthemen laut MEDLINE: Photoplethysmography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JST, JST Moonshot R&D.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoplethysmogram (PPG) signals are increasingly utilized in wearable and mobile healthcare applications due to their non-invasive nature and ease of use in measuring physiological parameters, such as heart rate, blood pressure, and oxygen saturation. Recent advancements have highlighted green-light photoplethysmogram (gPPG) as offering superior signal quality and accuracy compared to traditional red-light photoplethysmogram (rPPG). Given the deterministic chaotic nature of PPG signals’ dynamics, nonlinear time series analysis has emerged as a powerful method for extracting health-related information not captured by conventional linear techniques. However, optimal data conditions, including appropriate sampling frequency and minimum required time series length for effective nonlinear analysis, remain insufficiently investigated. This study examines the impact of downsampling frequencies and reducing time series lengths on the accuracy of estimating dynamical characteristics from gPPG and rPPG signals. Results demonstrate that a sampling frequency of 200 Hz provides an optimal balance, maintaining robust correlations in dynamical indices while reducing computational load. Furthermore, analysis of varying time series lengths revealed that the dynamical properties stabilize sufficiently at around 170 s, achieving an error of less than 5%. A comparative analysis between gPPG and rPPG revealed no significant statistical differences, confirming their similar effectiveness in estimating dynamical properties under controlled conditions. These results enhance the reliability and applicability of PPG-based health monitoring technologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyHumansHeart RateSignal Processing, Computer-AssistedAlgorithmsMonitoring, PhysiologicBlood PressureMaleAdultWearable Electronic Devices

Stichwörter der Autor:innen

computational efficiencydata reductionnonlinear dynamicsnonlinear time series analysisphotoplethysmographywearable devices

Autor:innen und Institutionen

  • Department of Intelligent Systems, Tokyo City University, 1-28-1 Tamazutsumi, Setagaya-ku, Tokyo 158-8557, Japan.
  • International Research Center for Neurointelligence, The University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-0033, Japan.

ORCID-Profile: Nina Sviridova

Förderung

  • JST
  • JST Moonshot R&D

Zitieren

APA

Sviridova, N., & Okazaki, S. (2025). Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram. Sensors. https://doi.org/10.3390/s25196232

Vancouver

Sviridova N, Okazaki S. Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram. Sensors. 2025. doi:10.3390/s25196232

BibTeX
@article{Sviridova2025,
  author = {Sviridova, Nina and Okazaki, Sora},
  title = {Data Reduction Methodology for Dynamic Characteristic Extraction in Photoplethysmogram},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25196232}
}
Kostenlos starten →