Validation of Novel Stride Length Model-Based Approaches to Estimate Distance Covered Based on Acceleration and Pressure Data During Walking
Sensors · 2025
DOI: 10.3390/s25196217 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Armelle-Myriane Ngueleu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Ca…. Hauptthemen laut MEDLINE: Walking, Gait. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Center for Interdisciplinary Research in Rehabilitation and Social Integration, Fonds de Recherche du Québec—Société et Culture.
Abstract (Originalsprache)
The ability to walk is essential in daily life, making walking outcomes key measures in clinical practice. This study aims to develop and validate two novel stride length model-based approaches for total distance estimation using a smart insole. Eight participants wore a pair of smart insoles. For a period of six minutes, each participant walked back and forth on a predefined 20 m pathway, and the numbers of round trips and strides taken were counted. Two stride length estimation approaches based on the director coefficients of acceleration data (Approach 1) and dynamic time warping (Approach 2) using smart insoles were used. The median accuracies of the total distance using Approach 1 are 98.92% [1.24%] (ICC = 0.992) and 98.69% [2.44%] (ICC = 0.994) for the right and left sides, respectively. For Approach 2, the average accuracies are 98.95% [0.18%] (ICC = 0.996) for the right side and 99.03% [0.14%] (ICC = 0.991) for the left side. The Mann–Whitney U test shows no statistically significant difference between the actual distance and smart insole for the total distance covered. Furthermore, there is no statistically significant difference between Approach 1 and Approach 2 for stride length. Although the sample size was small, the estimated total distance using the novel model-based algorithms appears to be accurate in comparison to the actual total distance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Interdisciplinary Research in Rehabilitation and Social Integration, Centre Intégré Universitaire de Santé et de Services Sociaux de la Capitale-Nationale, School of Rehabilitation Sciences, Faculty of Medici…
- Automation and interactive Robotic Laboratory (AIRL), Department of Applied Science, Université de Quebec à Chicoutimi, 555 Blvd. of University, Chicoutimi, QC G7H 2B1, Canada.
ORCID-Profile: Armelle-Myriane Ngueleu, Martin J-D Otis, Charles Sebiyo Batcho
Förderung
- Center for Interdisciplinary Research in Rehabilitation and Social Integration
- Fonds de Recherche du Québec—Société et Culture
Zitieren
APA
Ngueleu, A. M., Otis, M. J., & Batcho, C. S. (2025). Validation of Novel Stride Length Model-Based Approaches to Estimate Distance Covered Based on Acceleration and Pressure Data During Walking. Sensors. https://doi.org/10.3390/s25196217
Vancouver
Ngueleu AM, Otis MJ, Batcho CS. Validation of Novel Stride Length Model-Based Approaches to Estimate Distance Covered Based on Acceleration and Pressure Data During Walking. Sensors. 2025. doi:10.3390/s25196217
BibTeX
@article{Ngueleu2025,
author = {Ngueleu, Armelle-Myriane and Otis, Martin J-D and Batcho, Charles Sebiyo},
title = {Validation of Novel Stride Length Model-Based Approaches to Estimate Distance Covered Based on Acceleration and Pressure Data During Walking},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25196217}
}
EUVIMED